Cypress CY7C1427AV18, CY7C1416AV18, CY7C1418AV18, CY7C1420AV18 manual Switching Characteristics

Models: CY7C1418AV18 CY7C1420AV18 CY7C1427AV18 CY7C1416AV18

1 31
Download 31 pages 9.31 Kb
Page 23
Image 23

CY7C1416AV18, CY7C1427AV18

CY7C1418AV18, CY7C1420AV18

Switching Characteristics

Over the Operating Range [20, 21]

Cypress

Consor-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300 MHz

278 MHz

250 MHz

200 MHz

167 MHz

 

Parame-

tium Pa-

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

ter

rameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tPOWER

 

VDD(Typical) to the First Access [22]

1

1

1

1

1

ms

tCYC

tKHKH

K Clock and C Clock Cycle Time

3.3

8.4

3.6

8.4

4.0

8.4

5.0

8.4

6.0

8.4

ns

tKH

tKHKL

Input Clock (K/K

and C/C) HIGH

1.32

1.4

1.6

2.0

2.4

ns

tKL

tKLKH

Input Clock (K/K

and C/C) LOW

1.32

1.4

1.6

2.0

2.4

ns

tKHKH

tKHKH

K Clock Rise to

K

Clock Rise and C

1.49

1.6

1.8

2.2

2.7

ns

 

 

to C Rise (rising edge to rising

 

 

 

 

 

 

 

 

 

 

 

 

 

edge)

 

 

 

 

 

 

 

 

 

 

 

tKHCH

tKHCH

K/K

Clock Rise to C/C Clock Rise

0.0

1.45

0.0

1.55

0.0

1.8

0.0

2.2

0.0

2.7

ns

 

 

(rising edge to rising edge)

 

 

 

 

 

 

 

 

 

 

 

Setup Times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tSA

tAVKH

Address Setup to K Clock Rise

0.4

0.4

0.5

0.6

0.7

ns

tSC

tIVKH

Control Setup to K Clock Rise

0.4

0.4

0.5

0.6

0.7

ns

 

 

(LD, R/W)

 

 

 

 

 

 

 

 

 

 

 

tSCDDR

tIVKH

Double Data Rate Control Setup to

0.3

0.3

0.35

0.4

0.5

ns

 

 

Clock (K/K) Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

(BWS0, BWS1,

BWS

2,

BWS

3)

 

 

 

 

 

 

 

 

 

 

 

tSD [23]

tDVKH

D[X:0] Setup to Clock (K/K)

 

Rise

0.3

0.3

0.35

0.4

0.5

ns

Hold Times

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

tHA

tKHAX

Address Hold after K Clock Rise

0.4

0.4

0.5

0.6

0.7

ns

tHC

tKHIX

Control

Hold after K Clock Rise

0.4

0.4

0.5

0.6

0.7

ns

 

 

 

 

 

(LD, R/W)

 

 

 

 

 

 

 

 

 

 

 

tHCDDR

tKHIX

Double Data Rate Control Hold

0.3

0.3

0.35

0.4

0.5

ns

 

 

after Clock (K/K) Rise

 

 

 

 

 

 

 

 

 

 

 

 

 

(BWS0, BWS1,

BWS

2,

BWS

3)

 

 

 

 

 

 

 

 

 

 

 

tHD

tKHDX

D[X:0] Hold after Clock (K/K)

Rise

0.3

0.3

0.35

0.4

0.5

ns

Notes

21.When a part with a maximum frequency above 167 MHz is operating at a lower clock frequency, it requires the input timings of the frequency range in which it is being operated and outputs data with the output timings of that frequency range.

22.This part has an internal voltage regulator; tPOWER is the time that the power is supplied above VDD min initially before a read or write operation can be initiated.

23.For DQ2 data signal on CY7C1427AV18 device, tSD is 0.5 ns for 200 MHz, 250 MHz, 278 MHz, and 300 MHz frequencies.

Document Number: 38-05616 Rev. *F

Page 23 of 31

[+] Feedback

Page 23
Image 23
Cypress CY7C1427AV18, CY7C1416AV18, CY7C1418AV18, CY7C1420AV18 manual Switching Characteristics