CY7C1511V18, CY7C1526V18

CY7C1513V18, CY7C1515V18

Capacitance

Tested initially and after any design or process change that may affect these parameters.

Parameter

Description

Test Conditions

Max

Unit

CIN

Input Capacitance

TA = 25°C, f = 1 MHz, VDD = 1.8V, VDDQ = 1.5V

5.5

pF

CCLK

Clock Input Capacitance

 

8.5

pF

CO

Output Capacitance

 

6

pF

Thermal Resistance

Tested initially and after any design or process change that may affect these parameters.

Parameter

Description

 

Test Conditions

165 FBGA

Unit

 

Package

 

 

 

 

 

ΘJA

Thermal Resistance

 

Test conditions follow standard test methods and

16.3

°C/W

 

(Junction to Ambient)

 

procedures for measuring thermal impedance, in

 

 

 

 

 

accordance with EIA/JESD51.

 

 

ΘJC

Thermal Resistance

 

2.1

°C/W

 

 

 

(Junction to Case)

 

 

 

 

 

 

Figure 4. AC Test Loads and Waveforms

 

 

VREF = 0.75V

VREF

 

 

 

 

 

 

 

0.75V

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

Z0 = 50Ω

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

 

 

 

 

 

 

 

 

Under

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

 

 

 

 

 

 

 

 

 

 

 

 

 

ZQ

RQ =

250Ω

(a)

RL = 50Ω

VREF = 0.75V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VREF

 

 

 

 

 

 

0.75V

 

 

 

 

 

R = 50Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALL INPUT PULSES[22]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.25V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 pF 0.25V

 

 

 

0.75V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Under

ZQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Slew Rate = 2 V/ns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

 

 

 

 

 

 

RQ =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250Ω

 

 

 

 

 

 

 

 

 

 

INCLUDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JIG AND

 

 

 

 

 

 

(b)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCOPE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note

22.Unless otherwise noted, test conditions are based on signal transition time of 2V/ns, timing reference levels of 0.75V, Vref = 0.75V, RQ = 250Ω, VDDQ = 1.5V, input pulse levels of 0.25V to 1.25V, and output loading of the specified IOL/IOH and load capacitance shown in (a) of AC Test Loads and Waveforms.

Document Number: 38-05363 Rev. *F

Page 23 of 32

[+] Feedback

Page 23
Image 23
Cypress CY7C1515V18, CY7C1513V18 manual Capacitance, Thermal Resistance, Parameter Description Test Conditions Max Unit