5.2 Line Loopback
In the Line Loopback mode, serial data (from IN±) will loop through the serial input buffer and CDR block to the serial output buffer
(OUT±). Figure 5 shows the data path (bold line) of the Line Loopback mode. To select the Line Loopback mode:
1. SW1-3 (LINELOOP) must be in ON position
2. All other dip switch settings must be in their default positions as stated in Tabl e 4
3. TEST0, jumper J6 must be opened
4. Apply the Testing Hookup illustrated in Figure 8 to Figure 10