Installation Instructions

Electrical Connection (continued)

Connecting an Appliance Wire to the Range - Where Local Code Permits

WARNING

Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.

1.Remove the range electrical access cover from the back of the range.

2.If using a 4 wire connection, loosen the grounding screw and remove the neutral to ground jumper link.

3.Remove the conduit bracket from the bottom of the range electrical box.

Electrical

Access

Remove jumper on 4 Wire installations

Remove conduit bracket before strain relief installation

4.Disassemble and remove the strain relief from the appliance cord (not included). Insert the tabs on the two parts of

the strain relief into the hole on the bottom of the box and reassemble it so that the tabs are below the box and the strain relief itself is inside the box.

Strain Relief

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of range electrical

 

Reassemble with tabs

box

 

below and clamp above

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.Slide the end of the appliance cord into the strain relief from the bottom of the box

6.Connect the white (neutral) wire to the neutral terminal in the box.

7.Connect the L1 wire to the L1 power supply terminal in the box.

8.Connect the L2 wire to the L2 power supply terminal in the box.

9.If using a 4 Wire connection, connect the ground wire to the grounding screw inside the box.

10.Tighten the strain relief so that the appliance cord is held snuggly in place.

11.Replace the range electrical access cover.

L1 Terminal

Neutral Terminal

L2 Terminal

Jumper Removed

Grounding Screw

L2 Wire

Green Wire

White Wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1 Wire

Strain Relief

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 Wire Appliance

Cord Connection

L2

Neutral

L1Ground

14-50P Plug

14