Installation Instructions
Electrical Connection (continued)
Connecting an Appliance Wire to the Range - Where Local Code Permits
WARNING
Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit.
1.Remove the range electrical access cover from the back of the range.
2.If using a 4 wire connection, loosen the grounding screw and remove the neutral to ground jumper link.
3.Remove the conduit bracket from the bottom of the range electrical box.
Electrical
Access
Remove jumper on 4 Wire installations
Remove conduit bracket before strain relief installation
4.Disassemble and remove the strain relief from the appliance cord (not included). Insert the tabs on the two parts of
the strain relief into the hole on the bottom of the box and reassemble it so that the tabs are below the box and the strain relief itself is inside the box.
Strain Relief
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Bottom of range electrical |
| Reassemble with tabs | |||||||||||
box |
| below and clamp above | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5.Slide the end of the appliance cord into the strain relief from the bottom of the box
6.Connect the white (neutral) wire to the neutral terminal in the box.
7.Connect the L1 wire to the L1 power supply terminal in the box.
8.Connect the L2 wire to the L2 power supply terminal in the box.
9.If using a 4 Wire connection, connect the ground wire to the grounding screw inside the box.
10.Tighten the strain relief so that the appliance cord is held snuggly in place.
11.Replace the range electrical access cover.
L1 Terminal
Neutral Terminal
L2 Terminal
Jumper Removed
Grounding Screw
L2 Wire
Green Wire
White Wire
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| L1 Wire | ||
Strain Relief |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 Wire Appliance
Cord Connection
L2
Neutral
L1Ground
14-50P Plug
14