Configuration Settings

Power

1.Under Decoding Properties, go to

Configure > RFID > Power

2.Enable/disable Growing Power by selecting the checkbox. When dis- abled, a constant level of RF power is output when reading tags. When enabled, the level of RF power starts at a minimum level, and then increases to a maximum level, where it will remain for the duration of the painting operation.

3.Set Minimum/Maximum Read using the sliders.

Minimum Power: The minimum RF power level to use for reading tags. It only applies when Growing Power is enabled.

Maximum Power: The maximum RF power level to use for reading tags. If Growing Power is disabled, this is the power level used for the entire painting operation.

Read Limits

1.Under Decoding Properties, go to

Configure > RFID > Read Limits

Total Read Timeout: The maxi- mum amount of time spent per- forming an entire painting operation. If set to Infinite, painting will stop only when the trigger is released, a New Tag Time- out occurs, or the minimum number of tags have been read.

10

Falcon® 5500 RFID Mobile Hybrid Computer

Page 14
Image 14
Datalogic Scanning 5500 manual Power, Read Limits