POWERSCAN® D8530

SERIAL CONFIGURATION STRINGS

ENTER/EXIT CONFIGURATION COMMANDS

DESCRIPTION

 

STRING

Enter Configuration

 

$+

Exit and Save Configuration

$-

Restore Default

 

$+$*

Transmit Software Release

$+$!

Transmit Device Configuration in ASCII

$?$&

Save Custom Default

 

$+$0

Restore Custom Default

$+$1

These commands do not require $-

 

 

 

 

 

 

 

 

 

INTERFACE SELECTION

 

DESCRIPTION

 

STRING

RS-232

Standard

 

CPA0

WEDGE

for IBM AT

 

CPA1

USB

USB COM

 

CPA3

 

 

USB-KBD

 

CPA4

 

 

USB Bulk

 

CPA2

 

 

USB Generic HID

CPA5

 

 

 

 

 

 

 

 

RS-232

 

DESCRIPTION

 

STRING

Baud rate

 

1200

DAA00

 

 

 

2400

DAA01

 

 

 

4800

DAA02

 

 

 

9600

DAA03

 

 

 

14400

DAA04

 

 

 

19200

DAA05

 

 

 

38400

DAA06

 

 

 

57600

DAA07

 

 

 

115200

DAA08

Parity

 

none

DBA0

 

 

 

even

DBA2

 

 

 

odd

DBA1

Data bits

 

7

DCA0

 

 

 

8

DCA1

Stop bits

 

1

DCB0

 

 

 

2

DCB1

Handshake

none

DDA0

 

 

 

RTS/CTS

DDA2

 

 

 

XON/XOFF

DDA1

 

 

 

RTS always ON

DDA3

ACK/NACK Protocol

disabled

DDB0

 

 

 

enabled

DDB1

122