9) CONTROL CODES

10) CONT FORM LENGTH

Allows code selection listed in

Sets the page (label) size when the

Programmer’s manual.

‘SENSOR TYPE’ is set to continuous

Possible Values:

media.

 

Possible Values:

* (STD) Standard Codes

Range: 0 – 9999; default = *100

(ALT) Alternate Codes

 

(Units = .01 inch)

 

 

11) OOS MAXVOLT

12) TOF GAIN

Sets the media sensor level for the

Sets media sensor Top of Form gain

Out Of Stock condition.

value.

 

Possible Values:

Possible Values:

Range: 0 – 16; nominal = *2

Range: 0 – 15; nominal = *10

(Units = .1 volt)

 

 

 

 

13) TOF DELTA

14) TOF LOW

Sets the minimum media sensor

Sets the minimum media sensor reading

change required to signify a label

for paper (gap/notch) or mark

gap or mark.

(reflective).

Possible Values:

Possible Values:

Range: 0 – 50; nominal = *10

Range: 0 – 50; nominal = *0

(Units = .1 volt)

(Units = 0.1 volt)

 

 

15) LABEL WIDTH

16) SCALABLE FONT

Sets the label width.

Sets the number of memory blocks to

Possible Values:

allocate for scalable fonts.

Possible Values:

Range: 75 – 426; default = *426

 

 

(Units = .01 inch)

Range: 0 – 128; default = *64

 

(Units = 4K Bytes)

 

 

17) INTERNAL MODULE

18) LABEL ALIGNMENT

Sets the number of memory blocks to

Sets the label alignment method (see

allocate for the internal RAM

Section 4.6).

module.

Possible Values:

Possible Values:

YES

(user manually determines

 

Range: 0 – 128; default = *128

 

‘ALIGN LENGTH’)

(Units = 4K Bytes)

AUTO (printer determines ‘ALIGN

 

 

LENGTH’)

 

* NO

(no Label Alignment used)

22

M-4206

Page 28
Image 28
Datamax M-4206 manual Control Codes Form Length