Datamax M-4206 manual Align Length Stop Location

Models: M-4206

1 76
Download 76 pages 55.67 Kb
Page 29
Image 29

19) ALIGN LENGTH

20) STOP LOCATION

Leading edge distance of two

Sets label stopping (and in certain cases the starting)

successive labels. Must be entered if

location for different printer configurations.

‘LABEL ALIGNMENT’ is set to

Possible Values:

Yes (see Section 4.6).

 

 

 

Possible Values:

* AUTO

(Automatically sets the stop location. Installed

 

options will be ‘auto-sensed’ and the

 

 

 

 

0 – 999; default =100*

 

appropriate stop position will automatically

(Units = .01 inch)

 

be set. Host commands are ignored.)

 

 

 

HOST

(Sets stop position according to options

 

 

 

 

installed. If no options are installed the printer

 

 

 

 

sets stop location to the next label’s start of

 

 

 

 

print. Host commands will override.)

 

 

 

 

21) INPUT MODE

22) DPL EMULATION

Selects between the standard or

This instructs the firmware to process specific DPL data

template interpretation of incoming

(Start of Print, DPI, and Imaging function) according to

data.

 

 

the selected printer emulation.

Possible Values:

Possible Values:

* DPL

(printer constructs the label

* STANDARD

 

using the standard DPL

ALLEGRO (Allegro Emulation)

 

commands)

P PLUS (Prodigy Plus Emulation)

LINE

(printer constructs the label

PRODIGY (Prodigy Emulation)

 

using a preloaded template

 

 

 

 

 

form)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23) HEAT

 

 

 

 

 

Controls the ‘burn-time’ of the printhead. This is the equivalent of

 

 

Heat Setting on most label software programs.

 

 

Possible Values:

 

 

 

Range: 0 – 30; default = *10

; Note: All of the menu items listed in the previous section are stored in non-volatile memory.

M-4206

23

Page 29
Image 29
Datamax M-4206 manual Align Length Stop Location