Problem

Possible Cause

 

Solution

 

Label Alignment is

Label Alignment Length is

¾

Set Label Alignment to AUTO. Press and hold

 

 

FEED until

 

incorrect. Pressing

not correct. The default

 

paper moves for automatic Label Alignment length

 

 

 

 

FEED successively

Label Alignment Length is

 

measurement.

 

 

 

 

 

 

results in a label length

1.00”, and will result in

 

~OR~

 

longer than actual, one-

this behavior when any

 

 

 

 

 

 

 

inch.

larger label length is used

¾

Measure the label length and use the Setup Menu to set the new

 

 

 

 

without setting the

 

length. Print a Database Configuration label to ensure the new

 

 

 

 

appropriate length

 

length has been set.

 

 

 

 

 

 

Tear Mode is selected

Another present position

¾

Disable the Present Sensor.

 

but the label stop

has been determined.

 

~OR~

 

position (present

Enabling the Present

 

 

 

 

 

 

 

position) is not far

Sensor causes the label

¾

Ensure the host computer is not providing a Present Distance

enough forward.

stop position (present

 

shorter than is required for the Tear Bar.

 

 

 

 

 

position) to be

 

 

 

 

 

 

 

 

 

approximately 0.1” behind

 

 

 

 

 

 

 

 

 

the peel bar.

 

 

 

 

 

 

 

 

 

~OR~

 

 

 

 

 

 

 

 

 

The Present Adjust value

¾

Use the Setup Menu to modify the Present Adjust value.

 

 

 

 

is not correct.

 

 

 

 

 

 

 

 

 

Tear Mode is selected

Another present position

¾

Ensure the host computer is not providing a Present Distance

but the label stop

has been determined.

 

longer than is required for the Tear Bar.

 

position (present

 

 

 

 

 

 

position) is too far

~OR~

 

 

 

 

 

forward.

 

 

 

 

 

 

 

 

 

 

The Present Adjust value

¾

Use the Setup Menu to modify the Present Adjust value.

 

 

 

 

is not correct.

 

 

 

 

 

 

The

ERROR light

The label supply is empty

¾

Load media.

 

illuminates during label

 

 

 

 

 

 

alignment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M-4206

29

Page 35
Image 35
Datamax M-4206 manual Incorrect. Pressing Not correct. The default