Chapter 4

Troubleshooting and Maintenance

Vantage Pro2 Troubleshooting Guide

While your Vantage Pro2 weather station is designed to provide years of trouble-free operation, occasional problems may arise. If you are having a problem with your sta- tion, please consult this troubleshooting guide before calling Davis technical support. You may be able to quickly solve the problem yourself. Please see “Contacting Davis Technical Support” on page 53.

Note:

Refer to the ISS Installation Manual for additional troubleshooting information.

 

 

 

 

 

 

 

TABLE 4-1: TROUBLESHOOTING GUIDE

 

 

 

 

 

 

 

 

Problem

 

Solution

 

 

 

 

 

 

 

 

Display shows only

Indicates that console has rebooted. Hold the DONE key to re-

 

 

turn to Current Weather Mode. (Check time setting if power was

 

 

“RECEIVING FROM.....”

 

 

lost.)

 

 

 

 

 

 

 

 

 

 

Display is blank

Unit is not receiving power. Check the power adapter connec-

 

 

tions and/or replace batteries.

 

 

 

 

 

 

 

ISS not plugged in (cabled station). See ISS manual.

 

 

 

Sensors not transmitting (wireless station). See ISS (or oth-

 

 

 

er transmitter) manual.

 

 

 

Console not receiving (wireless station) - See “Trouble-

 

Display

Display shows dashes in

 

shooting Reception Problems” on page 35.

 

place of weather data

A reading has exceeded the limits indicated in the

 

 

 

specifications table.

 

 

 

Calibration numbers may be causing readings to exceed

 

 

 

 

display limits. Check calibration number and adjust if nec-

 

 

 

 

essary.

 

 

 

 

 

 

 

Console is sluggish or does

The console and display may not work below 32º F (0º C). Use

 

 

not work at low tempera-

an External Temperature sensor in low-temperature locations or

 

 

tures

install the console indoors.

 

 

 

Display shows “odd” values

You may have synchronized with another weather station near-

 

 

or missing values.

by. Change the transmission and reception IDs to a different ID.

 

 

 

Display “locks up”

Reset the console by removing AC and battery power then re-

 

 

storing power. If this occurs frequently in an AC-powered con-

 

 

 

sole, plug the AC power-adapter into a surge suppressor.

 

Humidity

 

 

 

 

 

Inside humidity seems too

Make sure the console is not near a humidifier or de-humidifier.

 

 

Check calibration number and adjust if necessary. If inside hu-

 

 

high or too low

midity is low, and inside temperature is too high, see “inside

 

 

 

temp” below. Also make sure the console backlight is not on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

 

For low readings, remove wind cups and check for friction

 

 

Wind speed reading seems

sources. Check the anemometer location. Is it sheltered from

 

too high or too low.

the wind? See ISS manual for additional wind speed

 

 

troubleshooting information.

 

Wind

 

 

 

 

Wind speed reads 0 either

The problem may be with the anemometer. Test anemometer

 

by spinning wind cups. Check reed switch fields on diagnostic

 

all the time or intermittently

 

 

 

screen (see page 37) and call technical support.

 

 

 

 

 

 

 

Dew

Dew Point reading seems

Check calibration numbers for temperature. Dew point depends

 

on temperature and outside humidity. Make sure they’re work-

 

too high or too low

 

 

 

ing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

Page 37
Image 37
Davis Instruments 6152C manual Chapter Troubleshooting and Maintenance, Vantage Pro2 Troubleshooting Guide, Speed, Wind