Vantage Pro2 Troubleshooting Guide
TABLE
| Problem |
| Solution | |
|
|
|
| |
| Outside temperature sen- | Check to see if ISS is near mechanical or radiant heat source. | ||
| Check calibration number and adjust if necessary. ISS or temp | |||
| sor reading seems too high | sensor may need to be relocated. See ISS or other transmitter | ||
|
| manual. | ||
|
|
| ||
|
| Move the console out of direct sunlight. Make sure that the con- | ||
Temperature |
| sole or sensor is not in contact with an exterior wall that heats | ||
Outside temperature | up in sunlight or when outside temperature rises. Make sure the | |||
may be hitting the ISS radiation shield. Relocate. See ISS man- | ||||
| Inside temperature sensor | console or sensor is not near a heater or other internal heat | ||
| reading seems too high | source (lamps, appliances, etc.). Also make sure the console | ||
|
| backlight is not on. Check calibration number and adjust if nec- | ||
|
| essary. | ||
|
| Check calibration number and adjust if necessary. Sprinklers | ||
| seems too low | ual. |
| |
|
|
| ||
|
|
| ||
|
| Make sure the console or other temperature sensor is not in | ||
| Inside temperature sensor | contact with an exterior wall that cools down when outside tem- | ||
| perature drops. Make sure the console or other temperature | |||
| reading seems too low | |||
| sensor is not near an air conditioning vent. Check calibration | |||
|
| |||
|
| number and adjust if necessary. | ||
|
|
|
| |
|
|
|
| |
|
|
|
| |
Direction |
|
|
| |
| • | Wireless model - check reception. See Reception Prob- | ||
Wind direction reading is |
| lems below. | ||
| • | Cabled model - cable may be faulty. | ||
| dashed out | |||
| If these steps do not reveal the problem, the anemometer may | |||
|
| be faulty. Call technical support. | ||
Wind |
|
| ||
Wind direction always says | Usually a problem in the ISS, either with the transmitter or ane- | |||
mometer cable. See the ISS manual for troubleshooting infor- | ||||
north | ||||
mation. | ||||
|
|
|
| |
Chill | Wind chill reading seems | Check calibration numbers for temperature. Wind chill depends | ||
| too high or too low | on temperature and wind speed. Make sure they’re working. | ||
|
|
| ||
|
|
|
| |
Heat | too high or too low | Check calibration numbers for temperature. The heat index de- | ||
sors are working. | ||||
| Heat Index reading seems | pends on temperature and outside humidity. Make sure the sen- | ||
|
| |||
|
|
|
| |
|
|
|
| |
Rain | No rain readings | Make sure | ||
| See the ISS manual. | |||
|
| |||
|
|
|
| |
|
|
|
| |
UV/Solar | Readings are too high | Can be caused by high thin cirrus clouds. | ||
| ||||
|
|
| ||
|
|
|
| |
Time | Incorrect times for sunrise | Check your latitude, longitude, time zone, and daylight savings | ||
time settings. Sunrise and sunset times are calculated from the | ||||
and sunset | ||||
console using all of these settings. | ||||
|
|
|
|
Troubleshooting Reception Problems
While we have tested the Wireless Vantage Pro2 radio extensively, each site and each installation presents its own issues and challenges. Obstructions, particularly metallic ones, often cut down your station’s reception distance. Be sure to test reception between the console and ISS, in the locations you intend to install them, before perma- nently mounting your ISS or other transmitter(s).
The console’s reception status displays at the lower right corner of the screen.
35