Davis Instruments 6152C manual Console Data Display Specifications

Models: 6152C

1 56
Download 56 pages 36.85 Kb
Page 51
Image 51

Console Data Display Specifications

Console Data Display Specifications

Historical Data . . . . . . . . . . . . . . . . . . . . . Includes the past 24 values listed un- less otherwise noted; all can be cleared and all totals reset.

Daily Data. . . . . . . . . . . . . . . . . . . . . . . . . Includes the earliest time of occur- rence of highs and lows; period be- gins/ends at 12:00 am.

Monthly Data . . . . . . . . . . . . . . . . . . . . . . Period begins/ends at 12:00 am on the first of every month.

Yearly Data. . . . . . . . . . . . . . . . . . . . . . . . Period begins/ends at 12:00 am on January 1st unless otherwise noted.

Current Graph Data . . . . . . . . . . . . . . . . . Current data appears in the right most column in the console graph and represents the latest value within the last period of the graph; totals can be set or reset.

Graph Time Interval . . . . . . . . . . . . . . . . . 1 min., 10 min., 15 min., 1 hour, 1 day, 1 month, 1 year (user-select- able, availability depends upon vari- able selected).

Graph Time Span . . . . . . . . . . . . . . . . . . . 24 Intervals + Current Interval (see Graph Intervals to determine time span).

Graph Variable Span (Vertical Scale) . . . . Automatic (varies depending upon data range); maximum and minimum value in range appear in ticker.

Alarm Indication . . . . . . . . . . . . . . . . . . . . Alarms sound for 2 minutes (time alarm is 1 minute) if operating on battery power. Alarm message displays in ticker as long as threshold is met or exceeded. Alarms can be silenced, but not cleared, by pressing DONE.

Transmission Interval . . . . . . . . . . . . . . . . Varies with transmitter ID code - from 2.25 seconds (ID1 = shortest) to 3 seconds (ID8 = longest).

Update Interval . . . . . . . . . . . . . . . . . . . . . Varies with sensor - see individual sensor specs.

Forecast:

Variables Used . . . . . . . . . . . . . . . . . Barometric reading & trend, wind speed & direction, rainfall, tempera- ture, humidity, latitude & longitude, time of year.

Update Interval . . . . . . . . . . . . . . . . . 1 hour

Display Format . . . . . . . . . . . . . . . . . Icons on top center of display; de- tailed message in ticker at bottom.

Variables Predicted . . . . . . . . . . . . . . Sky condition, precipitation, temper- ature changes, wind direction and speed changes.