Davis Instruments 6152C manual Variable Required Resolution Range Nominal Sensors

Models: 6152C

1 56
Download 56 pages 36.85 Kb
Page 53
Image 53

Weather Data Specifications

Weather Data Specifications

Variable

Required

Resolution

Range

Nominal

Sensors

Accuracy (+/-)

 

 

 

 

 

 

 

 

Solar Radiation

Solar sensor

1 W/m2

0 to 1800 W/m2

5% of full scale

Inside

Included in

0.1°F; 0.1°C

+32° to +140°F;

1°F; 0.5°C

Temperature

Console

0 to +60°C

 

 

 

 

 

 

 

Outside

ISS, Temp

0.1°F; 0.1°C

-40°to +150°F;

1°F; 0.5°C

Station or Temp

Temperature***

-40°to +65°C

Hum Station

 

 

 

 

 

 

 

ISS, Temp

 

 

 

Extra Temperature

Station, Temp

1°F; 1°C

-40°to +150°F

1°F; 0.5°C

Hum Station,

-40°to +65°C

 

Leaf Soil Station

 

 

 

 

 

 

 

or Soil Station

 

 

 

Heat Index

ISS or Temp/

1°F; 1°C

-40° to +165°F;

3°F (1.5°C)

Hum Station

-40°to +74° C

 

 

 

Temp-Hum-Sun-

ISS & Solar

1°F; 1°C

-90°to +165°F;

4°F (2°C)

Wind index

Radiation

-68°to +74° C

(THSW)

 

 

 

 

 

 

 

 

 

 

 

Time

Included in

1 min

24 hours

8 sec./mon.

Date

Console

1 day

month/day

8 sec./mon.

 

 

 

 

 

UV Index

 

0.1 Index

0 to 16

5% of full scale

 

UV Radiation

 

 

 

UV Dose

0.1 MED < 20,

0 to 199 MEDs

5%

 

1 MED > 20

 

 

 

 

Wind Direction

 

1°

0 to 360°

3°

 

 

 

 

 

Compass Rose

 

22.5°

16 compass pts

0.3 compass pt

 

Anemometer

 

 

 

Wind Speed (large

1 mph; 1 kt; 0.4 m/

2 to 180 mph;

greater of

 

2 to 156 kts

2 mph/kts;

cups)

 

s; 1 km/h

3 to 290 km/h,

1 m/s; 3 km/h

 

 

 

1 to 80 m/s

or 5%

Wind Chill

ISS

1°F; 1°C

-110°to +135°F

2°F;1°C

-79°to +57°C

 

 

 

 

***Outside temperature accuracy is based on the temperature sensor itself and not on the sensor and the passive shielding together. The solar radiation induced error for standard ration shield: +4°F (2°C) at solar noon; for fan aspirated radiation shield: +0.6°F (0.3°C) at solar noon (insolation = 1040 W/m2, avg. wind speed2 mph (1 m/s), reference: RM Young Model 43408 Fan-Aspirated Radiation Shield).