A MESSAGE TO OUR CUSTOMERS

Thank you for selecting this DCS Professional Cooktop. Because of this appliance’s unique features we have developed this Use and Care Guide. It contains valuable information on how to properly operate and maintain your new appliance for years of safe and enjoyable cooking.

To help serve you better, please fill out and submit your Ownership Registration by visiting our website at www.dcsappliances.com and selecting “Customer Service” on the home page and then select “Ownership Registration” or submit the enclosed Ownership Registration Card to the address below. In addition, keep this guide handy, as it will help answer questions that may arise as you use your new appliance.

For your convenience, product questions can be answered by a DCS Customer Care Representative by phone:

1-888-281-5698, email: support@dcsappliances.com, or by mail:

Fisher & Paykel Appliances, Inc.

 

Attention: DCS Customer Care

 

5900 Skylab Road

 

Huntington Beach, CA 92647

www.dcsappliances.com

NOTE: Please write the Model and Serial Number on this page for references (located on rating plate on the right side of the unit).

MODEL NUMBER

SERIAL NUMBER

WARNING!

Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, using or servicing this equipment.

WARNING!

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

DANGER

If You Smell Gas:

1.Do not try to light any appliance.

2.Do not touch any electrical switch; do not use any phone in your building.

3.Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

4.If you cannot reach your gas supplier, call the fire department.

5.Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING!

To reduce the risk of injury to persons in the event of a cooktop grease fire, observe the following: Turn burner off first. Smother flames with a close-fitting lid, cookie sheet, metal tray, baking soda or use a dry chemical or foam- type fire extinguisher. Be careful to prevent burns. If the flames do not go out immediately evacuate and call the fire department. Never pick up a flaming pan - You may be burned. DO NOT USE WATER ON GREASE FIRES, including wet dishcloths or towels - a violent steam explosion will result. Use an extinguisher ONLY if:

1.You know you have a Class ABC extinguisher, and you already know how to operate it.

2.The fire is small and contained in the area where it started.

3.The fire department is being called.

4.You can fight the fire with your back to an exit.

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.

1

Page 3
Image 3
DCS CP-366, CP-484GG, CP-485GD, CP-486GL, CP-364GL, CP-486GD, CP-364GD manual Message to OUR Customers, If You Smell Gas

CP-364GD, CP-486GD, CP-364GL, CP-366, CP-486GL specifications

DCS (Dual Control Systems) has made significant strides in the world of dynamic control solutions, with their new line of products, namely the CP-484GG, CP-485GD, CP-486GL, CP-366, and CP-364GL. Each model is designed with a unique set of features and advancements that cater to various applications within industrial and commercial settings.

The CP-484GG is particularly noteworthy for its enhanced graphical user interface, offering operators intuitive touch controls and customizable layouts. This model boasts a high-resolution display, making it easier for users to monitor system performance in real time. The CP-484GG is built on a robust platform that supports multi-protocol communication, ensuring seamless integration with existing control systems.

Next in line, the CP-485GD emphasizes the importance of data processing speed. With an embedded intelligent processing unit, the CP-485GD can handle complex calculations and manage multiple control loops simultaneously without sacrificing performance. One of its standout features is the advanced predictive maintenance technology that anticipates potential failures before they occur, reducing downtime and maintenance costs significantly.

The CP-486GL takes innovation a step further with its focus on energy efficiency. Designed to minimize power consumption while maximizing output, this model incorporates energy harvesting technology that captures and reuses energy within the system. The CP-486GL is compatible with renewable energy sources, making it a sustainable choice for modern facilities looking to decrease their carbon footprint.

The CP-366, on the other hand, is engineered for versatility. This compact control panel offers a wide range of I/O options, allowing users to configure it for various applications. The CP-366 comes equipped with high-speed data logging capabilities, enabling detailed analysis of operational data over time, which is crucial for process optimization.

Lastly, the CP-364GL stands out for its durability and rugged design. Built to withstand harsh environmental conditions, the CP-364GL is ideal for use in outdoor settings or industrial areas where exposure to the elements is a concern. Its corrosion-resistant materials and IP67 rating make it an excellent choice for demanding applications.

In summary, DCS's CP-484GG, CP-485GD, CP-486GL, CP-366, and CP-364GL reflect the company's commitment to innovation, efficiency, and reliability in control solutions. Each model comes equipped with cutting-edge technologies that enhance performance and adaptability for a range of industries, paving the way for smarter, safer, and more efficient operations.