If the active reference source is lost, the unit will select the next option in the sequence.
If the
Once slaved, the unit can internally multiply the reference input sample rate by 2 or 4, if required, by pressing the Multiplier button. The Master Clock must be set to a suitable sample rate:
Master Clock Sample | dCS 904 Sample Rate (kS/s) | |
Rate (kS/s) |
|
|
32 | 32 | |
44.1 | 44.1 or 88.2 or 176.4 | |
48 | 48 or 96 or 192 | |
88.2 | 88.2 or | 176.4 |
96 | 96 or | 192 |
Table 1 Reference Clock and Sample Rates
For Menu operation as the Menu Down button, see the section “The Software
Output Format | Menu | Up |
The Output Format button is dual function – on its own (blue type on the front panel) it sets the output format (single, dual, quad AES, etc). With the other menu buttons ( white type on the front panel) it is the Up button.
Pressing the Output Format button repeatedly causes the output format to cycle through the allowed options from the sequence:
Single AES ... Dual AES ... Quad AES ... Single AES ... etc.
If any format is not available at that sample rate, it is skipped from the sequence.
Mode DisplayThe single digit LED mode display to the right of the Format button shows the output format:
Display | Output Format |
0 | DSD mode, AES outputs turned off |
1 | Single AES |
2 | Dual AES |
3 | P3D mode |
4 | Quad AES or 4 wire DSD |
Table 2 Output Data format indication, higher sample rates
When the Output Format is selected, the main display briefly shows the format code:
Manual part no: DOC135904 iss 2B2 | Page 15 | 135904ma2b2.pdf file available from website |
Contact dCS on + 44 1799 531 999 | email to: more@dcsltd.co.uk |
(inside the UK replace + 44 with 0) | web site: www.dcsltd.co.uk |