dCS 904 User Manual

Manual for Software Version 1.5x and 1.36

dCS Ltd

June 2000

 

 

Ref In

Sets the mode of the AES Reference In/Out connectors. The options are:

Loop

Loops the input through to the output, with no

 

termination resistor (termination is then about

 

1kohm, so several units can be daisy chained).

Loop.t

As above, but terminates the input. Use at the end

 

of a daisy chain.

Int

The output (and input in parallel – beware!) is

 

internally driven, with the same signal as AES 1.

A-SL

Turns Auto-slaving On or Off. When set to On, connecting an AES/EBU reference or a word clock in causes the unit to slave and lights the Slave LED. If both are present, the unit picks the highest priority one (AES/EBU) unless the Master/Slave button is used to move down the priority list. When set to Off, the unit does not react when a reference is connected.

Offst

Trims the appropriate VCXO frequency in master mode, by up to ±9.9ppm in 0.1ppm steps. Use the Up and Down buttons to change this setting, hold a button down to accelerate the change. The trim is remembered.

Loc

Panel Lock, normally Off. Set to On to prevent unauthorised changes using buttons. The menu has to be accessed to turn the lock off again.

End

Exits the menu.

Manual part no: DOC135904 iss 2B2

Page 23

135904ma2b2.pdf file available from website

Contact dCS on + 44 1799 531 999

email to: more@dcsltd.co.uk

(inside the UK replace + 44 with 0)

web site: www.dcsltd.co.uk