In Quad AES mode, ensure that AES 1, 2, 3 & 4 outputs are correctly connected to the corresponding inputs on the destination equipment. See the manual of the destination equipment for information.

One output channel is low or absent

Check that all cables are connected correctly and not damaged. Damaged cables are a VERY common source of malfunctions!

Check that the balance is not offset elsewhere in the system.

If the level trimmers on the rear panel have been adjusted, check that one has not been set much lower than the other.

Clicks or crackles occur on the outputs

Check that all cables are connected correctly and not damaged.

Check that the overload LED does not light.

The unit fails to slave to a Master Clock

Press the Master/Slave button to select Slave mode. If a suitable reference is connected, the LED should light and the unit should lock after a few seconds.

Check that the Reference In or 75R In cable is connected correctly and not damaged.

Check that the Master Clock is switched on, set to the right sample rate and does not require re-calibration.

Connect a different piece of digital equipment to test the locking capability of the unit. If the condition persists, contact your Distributor or dCS.

The unit slaves to Word Clock but not AES/EBU

This can be caused by erroneous system messages. Contact your dealer or dCS for advice.

The Overload indicator will not go out

Remove any input and reference input. If the condition persists, contact your dealer or dCS - the unit may be faulty.

External meter does not show overload, dCS 904 does.

The dCS 904 monitors a number of internal points and data word values in its calculation of overload. This may cause it to indicate an overload while the final external data word may not show it - for example with a very narrow but large spike, that the low pass decimation filter may broaden out sufficiently that the output data does not saturate. It is likely that if the dCS 904 says it is in overload, it is. You can choose to ignore it!

Some digital meters are quite insensitive to overloads. Such equipment may include a sensitivity setting, where an overload is only flagged when a number of consecutive digital words saturate - typically 1, 2, 4 or 8 consecutive samples. There is some justification for this - single saturation events are not always audible. The dCS 904 flags their presence - it is up to the recording engineer to decide what to do about it.