Stacking Dell PowerConnect 7000 Series Switches
Page 10
4. Reload the stack command. This resets the entire stack. The switches stop forwarding during
the reset.
5. When the stack has reloaded, check the running firmware vers ion using the show version
command. Check that all stack members have joined the stack using the show stack
command. Members that failed to update may be recovered us ing the manual update
procedure described in the following section.
6. If successful, disable firmware synchronization on the s tack and save the running configuration.
Manual Update
The administrator can perform firmware updates on the stack by using the CLI or the Web interface.
From the CLI, use the copy ftp command, which uses the FTP protocol for file tra nsfer. To update
the firmware by using the Web interface, use the options a vailable on the System > File Management
> File Download from Server page.
NOTE: When stacked, the PC7000 switches require that the sa me version of firmware be installed on
every switch member.
When connected in stack, the copy ftp or copy tftp commands will distribut e the downloaded
image to all the connected units of the stack.
In the following output, the image with a file name of image.stk is downloaded from the FTP server
with an IP address of 10.27.64.141.
console#copy ftp ftp://10.27.64.141/image.stk image user admin password
test1234