Stacking Dell PowerConnect 7000 Series Switches

If PoE is enabled on a switch port shortly before a master failover and the hardware status change had not yet been communicated to the backup unit, the switch will continue to provide PoE power even though PoE is not enabled for the port in the configuration on the new master. The user can correct this configuration mismatch by re-enabling PoE on the port.

Stack Member Failover

When a unit in the stack fails, the master unit removes the failed unit from the stack. No changes or configuration settings are applied to the other stack members; however, dynamic protocols will try to re-converge as the topology could change because of the failed unit. When there are no connected ports on the failed unit, the stack will be intact without any changes.

Failover Scenarios

This section describes examples of what happens when a stack member or the master unit fails.

Scenario 1

In this example, the stack has four members that are connected through a daisy-chain.

Switch 1

Switch 2 Standby

Switch 3 Master

Switch 4

When all four units are up and running, the show switch CLI command gives the following output:

console#show switch

Switch

Managemen

Standby

Preconfig

Plugged-in

Switch

Code

Status

Status

Model ID

Model ID

Status

Version

------

----------

-------------

--------- --------

------------ --------

1

Stack Mbr

Standby

PCT7048

PCT7048

OK

4.0.0.6

2

Stack Mbr

 

PCT7048

PCT7048

OK

4.0.0.6

3

Mgmt Sw

 

PCT7048

PCT7048

OK

4.0.0.6

4

Stack Mbr

 

PCT7048

PCT7048

OK

4.0.0.6

At this point, if Unit 2 is powered off or rebooted due to an unexpected failure, show switch gives the following output: