3

Troubleshooting Dell Storage MD1280 components

This section contains basic troubleshooting tasks for components inside the Dell Storage MD1280 enclosure.

Troubleshooting fan modules

About this task

To troubleshoot fan modules, complete the following tasks:

Steps

1.Determine the status of the fan module LEDs.

If the fan fault LED glows, it implies that the fan module has failed.

2.Reseat the fan module by removing and reinstalling it.

NOTE: Allow the enclosure to identify the fan module and determine fan’s status.

Troubleshooting PSUs

About this task

To troubleshoot PSUs, complete the following tasks:

Steps

1.Determine the status of the PSU LEDs.

a.If the PSU fault LED glows, it implies that the PSU has failed.

b.If the Power OK LED is not glowing, check the power cord and power source into which the PSU is inserted:

1.Connect another device to the power source and check whether the device works.

2.Insert power cord to a different power source.

3.Replace the power cord.

c.If the AC fault LED glows, this PSU is not supplying power, though the other PSU may still be supplying the power.

2.Reseat the PSU by removing and reinstalling it.

NOTE: Allow the enclosure to identify the PSU and determine PSU’s status.

Troubleshooting DDICs

About this task

To troubleshoot DDICs, complete the following tasks:

25

Page 25
Image 25
Dell manual Troubleshooting Dell Storage MD1280 components, Troubleshooting fan modules, Troubleshooting PSUs