Troubleshooting Your System 105
4
Let the system dry thoroughly for at least 24 hours.
5
Close the system. See "Closing the System" on page55.
6
Reconnect the system to the electrical outlet, and turn on the system and
attached peripherals.
If the system does not start properly, see "Getting Help" on page127.
7
If the system starts properly, shut down the system and reinstall all of the
expansion cards that you removed. See "Installing an Expansion Card" on
page75.
8
Run the appropriate online diagnostic test. See "Using Dell PowerEdge
Diagnostics" on page 117.
If the tests fail, see "Getting Help" on page127.
Troubleshooting a Damaged System
Problem
System was dropped or damaged.
Action
CAUTION: Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.
1
Open the system. See "Opening the System" on page 54.
2
Ensure that the following components are properly installed:
Expansion cards
Power supplies
•Fans
3
Ensure that all cables are properly connected.
4
Close the system. See "Closing the System" on page55.
5
Run the system board tests in the system diagnostics. See "Running the
System Diagnostics" on page117.
If the tests fail, see "Getting Help" on page127.