Image 130

Error Code

Message Information

 

 

 

 

5.

If the issue persists, see Getting Help.

FAN0000

Message

Fan <number> RPM is less than the lower warning threshold.

 

 

Details

Fan operating speed is out of range.

 

Action

Remove and reinstall the fan. If the issue persists, see Getting Help.

FAN0001

Message

Fan <number> RPM is less than the lower critical threshold.

 

 

LCD Message

Fan <number> RPM is outside of range. Check fan.

 

Details

Fan operating speed is out of range.

 

Action

Remove and reinstall the fan. If the issue persists, see Getting Help.

FAN1201

Message

Fan redundancy is lost.

 

 

LCD Message

Fan redundancy is lost. Check fans.

 

Details

Fan has failed.

 

Action

Remove and reinstall failed fans or install additional fans.

HWC1001

Message

The <name> is absent.

 

 

LCD Message

The <name> is absent. Check hardware.

 

Details

The absent device may be necessary for proper operation. System

 

 

functionality may be degraded.

 

Action

Reinstall or reconnect the hardware.

HWC2003

Message

The storage <name> cable is not connected, or is improperly

 

 

 

connected.

 

LCD Message

Storage <name> cable or interconnect failure. Check connection.

 

Details

The cable may be necessary for proper operation. System

 

 

functionality may be degraded.

 

Action

Check if the cable is present, then reinstall or reconnect.

HWC2005

Message

The system board <name> cable is not connected, or is improperly

 

 

 

connected.

 

LCD Message

System board <name> cable connection failure. Check connection.

 

Details

The cable may be necessary for proper operation. System

 

 

functionality may be degraded.