| Chapter 5 | |
Group 4: Input Function Parameters |
|
| |||
|
|
|
| ||
Potentiometer Bias Frequency | Unit: 0. 1 | ||||
| Settings | d0.0 to d100.0% | Factory Setting: d0.0 | ||
|
|
|
| ||
Potentiometer Bias Polarity |
|
| |||
|
|
|
| Factory Setting: d0 | |
| Settings | d0 | Positive Bias |
|
|
|
| d1 | Negative Bias |
|
|
|
|
| |||
Potentiometer Frequency Gain | Unit: 1 | ||||
| Settings | d1 to d200% | Factory Setting: d100 | ||
|
|
|
| ||
Potentiometer Reverse Motion Enable |
|
| |||
|
|
|
| Factory Setting: d0 | |
| Settings | d0 | Forward motion only |
|
|
|
| d1 | Reverse motion enable (must be negative bias) | ||
|
|
|
|
|
|
Example 1:
The following is the most common method. Set parameter
Example 2:
In this example with the potentiometer set to 0V the Output Frequency is 10 Hz. The
Revision August 2006, SE08, SW V2.61 |