Delta Tau 4Ax-602804-xHxx manual E1 Watchdog Timer Disable, E2 CPU Mode Operation

Models: 4Ax-602804-xHxx

1 35
Download 35 pages 53 Kb
Page 16
Image 16

MACRO-CPU Hardware Reference

E1: Watchdog Timer Disable

Rev -105

Rev -104

Jumper

Description

Default

and Later

and Earlier

Type

 

 

Location

Location

 

 

 

 

 

 

Remove jumper to enable Watchdog Timer.

not jumpered

B-1

F-1

2-PIN

Jump pins 1 and 2 to disable Watchdog Timer (for test

 

 

 

 

purposes only)

 

 

 

 

 

 

 

 

 

 

 

E2: CPU Mode Operation

Rev -105

Rev -104

Jumper

Description

Default

and Later

and Earlier

Type

 

 

Location

Location

 

 

 

 

 

 

Jump pins 1 and 2 for firmware download through serial

Pin 2-3

D-2

D-1

3-PIN

port.

 

 

 

 

Jump pins 2 and 3 for normal operation.

 

 

 

 

 

 

 

 

 

 

 

E3: Serial Port Baud Rate

Rev -105

Rev -104

Jumper

Description

Default

and Later

and Earlier

Type

 

 

Location

Location

 

 

 

 

 

 

Jump pins 1 and 2 for 9600-baud serial port operation.

not jumpered

E-3

E-2

2-PIN

(Required for Yaskawa interface).

 

 

 

 

Remove jumper for 38400-baud serial port operation.

 

 

 

 

 

 

 

 

 

 

 

E4: Power Supply-Loss Control (±15Vdc Supply Monitor)

Rev -105

Rev -104

Jumper

Description

Default

and Later

and Earlier

Type

 

 

Location

Location

 

 

 

 

 

 

Jump pins 1 and 2 to disable servo outputs on loss of +5V,

not jumpered

 

 

 

+15V, or –15V power supply.

 

E-3

E-2

2-PIN

Remove this jumper to monitor +5Vdc power supply only.

 

 

 

 

±15V supply monitoring is not usually required for

 

 

 

 

applications without DACs or A-D converters.

 

 

 

 

 

 

 

 

 

 

 

12

3U MACRO-CPU Jumper and Switch Configurations

Page 16
Image 16
Delta Tau 4Ax-602804-xHxx manual E1 Watchdog Timer Disable, E2 CPU Mode Operation, E3 Serial Port Baud Rate