MACRO-CPU Hardware Reference

MACRO STATION CHARACTER DISPLAY

The Compact MACRO Station has a single hexadecimal character display on the CPU/Interface Board that provides useful information as to the status of the station. The display can show the following values:

Value

Meaning

(Blank)

Ring not active

0-8

Operation OK; value is # of motors enabled

9

(reserved for future use)

A

Amplifier fault

B

Ring break fault

C

CPU failure fault

D

Ring data error

E

Loss-of-encoder fault

F

Other failure