Denon DN-M991R English, @9 REMOTE connector, Display Window #0 TRACK NO. indicator

Models: DN-M991R

1 41
Download 41 pages 41.85 Kb
Page 10
Image 10
@9 REMOTE connector

ENGLISH

@9 REMOTE connector

This is a parallel remote connector. Use it to control the DN-M991R with dry contact circuit connections.

Applicable connector: 25-pin D-sub (male)

Connector signal layout:

Pin No.

Hot Start ON

 

Hot Start OFF

 

Level

 

 

 

 

Signal name

I/O

Signal name

I/O

 

 

 

 

 

 

 

 

1

FG

FG

 

14

PLAY CODE 1 tally

O

PLAY tally

O

TTL (lol=20 mA)

2

PLAY CODE 1 command

I

PLAY command

I

HCMOS (li–3 mA)

15

PLAY CODE 2 tally

O

PAUSE tally

O

TTL (lol=20 mA)

3

PLAY CODE 2 command

I

PAUSE command

I

HCMOS (li–3 mA)

16

PLAY CODE 3 tally

O

STDBY/CUE tally

O

TTL (lol=20 mA)

4

PLAY CODE 3 command

I

STDBY/CUE command

I

HCMOS (li–3 mA)

17

PLAY CODE 4 tally

O

END CUE tally

O

TTL (lol=20 mA)

5

PLAY CODE 4 command

I

TRACK (+) command

I

HCMOS (li–3 mA)

18

Tally common

O

Tally common

 

6

PLAY CODE 5 command

I

TRACK (–) command

I

HCMOS (li–3 mA)

19

REPEAT command

I

REC command

I

HCMOS (li–3 mA)

7

STOP command

I

SEARCH (FWD) command

I

HCMOS (li–3 mA)

20

REPEAT tally

O

CUE tally

O

TTL (lol=20 mA)

8

LOAD command

I

SEARCH (REV) command

I

HCMOS (li–3 mA)

21

LOAD tally

O

REC tally

O

TTL (lol=20 mA)

9

FADER START command

FADER START command

I

PHOTO COUPLER

22

Tally power supply

O

Tally power supply

+5 V, 20 mA

10

FADER START return &

Command common

(li=10 mA)

23

Command common

Command common

 

11

Reserved

REC E.O.M.

 

24

Reserved

E.O.M. tally

O

DRY CONTACT

12

Reserved

Reserved

 

25

Reserved

E.O.M. tally

O

DRY CONTACT

13

Hot Start ON (Low)

Hot Start OFF (High)

I

HCMOS (li–3 mA)

 

 

 

 

 

 

NOTES:

The tally output pin has open collector IC specifications (Imax. 20 mA, Vmax. 5 V), but the maximum supply current is 80 mA, so use with a total load current of 80 mA or less.

13 Pin enable when Hot start (Preset 36)) set up off mode.

(3) Display Window

#0 TRACK NO. indicator

This lights When the track number display shows the selected track number.

#1 PROGRAM indicator

• This lights when the Program play mode is set.

#2 DISC NAME/TRACK NAME/DATE indicators

“DISC NAME” lights when the disc name is displayed on the character display, “TRACK NAME” lights when the track name is displayed, and “DATE” lights when the date is displayed.

#3 Level display

This displays the playback level during playback, the input level during recording.

#4 EDIT indicator

• This lights when the edit mode is set.

#5 TOC indicator

This lights when it is necessary to rewrite the TOC (UTOC) due to editing, etc

This flashes while the TOC (UTOC) is being written.

#6 DIGITAL IN indicator

This lights (or flashes) when the digital input signal is selected.

The indicator flashes when the digital signal is unlocked and remains lit when the digital signal is locked.

#7 CUE indicator

This lights for approximately 3 seconds when the position at which a cue signal is set is played.

The indicator flashes when the standby mode is set at a position at which a cue signal is set.

#8 EOM indicator

This lights when the EOM is preset, and starts flashing when the EOM set time is reached.

#9 REPEAT indicator

• When this indicator is lit, playback is repeated. $0 EJECT LOCK indicator

When this indicator is lit, the eject lock function is set and the cartridge is not ejected even when the eject button is pressed.

$1 Character display

This displays disc names, track names and the date.

Various instructions are displayed here during presetting, programming, editing, etc.

$2 NEXT No. display

This displays the number of the next track to be played.

The program number is displayed during program input and editing.

During recording, this indicates the digital input signal’s sampling frequency.

When the playback pitch is changed, the pitch value flashes for 3 seconds.

10

Page 10
Image 10
Denon DN-M991R English, @9 REMOTE connector, Display Window #0 TRACK NO. indicator, #1 PROGRAM indicator, #3 Level display