TROUBLESHOOTING
Continued
OBSERVED FAULT | POSSIBLE CAUSE | SOLUTION | |
|
|
|
|
The fan comes on but the | 1. Ignitor is not functioning | 1. | A) Check the connections |
flame does not light or does |
|
| of the ignition cables to the |
not remain lit |
|
| electrodes and transformer |
|
|
| B) Check the position of the |
|
|
| electrodes and the distance |
|
|
| between them, in accordance |
|
|
| with the diagram on page 7 |
|
|
| C) Check that the electrodes |
|
|
| are clean |
|
|
| D) Replace the ignition |
|
|
| transformer |
| 2. Faulty flame control | 2. | Replace the flame control |
| 3. | 3. | Clean or replace the photo- |
| cell |
| electric cell |
| 4. Fuel is not reaching the burner | 4. | A) Check that the connection |
| or a sufficient amount is not |
| between the pump and the |
| arriving |
| motor is intact |
|
|
| B) Check that air has not fil- |
|
|
| tered into the fuel circuit, check |
|
|
| the tubes and the filter seal |
|
|
| C) Clean or, if necessary, |
|
|
| replace the nozzle |
| 5. Solenoid valve is not working | 5. | A) Check the electrical con- |
|
|
| nection |
|
|
| B) Check the LI thermostat |
|
|
| C) Clean or, if necessary, |
|
|
| replace the solenoid valve |
|
|
|
|
The fan comes on and the flame | 1. Insufficient air for combustion | 1. | A) Remove anything block- |
lights, but produces smoke |
|
| ing or obstructing the aspira- |
|
|
| tion and/or airflow ducts |
|
|
| B) Check the position of the |
|
|
| air regulation ring |
|
|
| C) Clean the burner disc |
| 2. Too much air for combustion | 2. | Check the position of the air |
| 3. Fuel is dirty or contains water |
| regulation ring |
| 3. | A) Replace the fuel with | |
|
|
| clean fuel |
|
|
| B) Clean the fuel filter |
| 4. Air has filtered into the fuel | 4. | Check the condition of the |
| circuit |
| tubes and the seal of the fuel |
| 5. Inadequate quantity of fuel in |
| filter |
| 5. | A) Check the pump pressure | |
| burner |
| B) Clean or replace the nozzle |
| 6. Too much fuel in burner | 6. | A) Check the pump pressure |
|
|
| B) Replace the nozzle |
|
|
|
|
The heater does not turn off |
| 1. | Replace the solenoid valve |
|
|
|
|
The fan does not switch off | 1. Faulty fan thermostat | 1. | Replace the FA thermostat |