SPECIFICATIONS
Model Size |
|
|
|
Maximum Output Rating (Btu/Hr) | 158,000 | 278,000 | |
Net Output Rating (Btu/Hr) |
| 133,000 | 234,400 |
Fuel | Use only kerosene, #1/#2 diesel/fuel oil, JET A or | ||
Fuel Tank Capacity (U.S. Gal./Liters) | 17/65 | 28/105 | |
Fuel Consumption |
|
|
|
(Gal. Per Hr/Liters Per Hr) |
| 1.27/4.81 | 2.22/8.40 |
Pump Pressure (psi) |
| 145 | 174 |
Electric Requirements |
| 120 V/60 HZ (Same Both Models) | |
Amperage (Normal Run) |
| 4.8 | 8.5 |
Motor RPM |
| 2850 | 3490 |
Hot Air Output (CFM) |
| 1,060 | 1,940 |
Shipping Weight |
| 190/86 | 320/145 |
(Approximate lbs./kg) |
|
|
|
Heater Weight without Fuel |
| 161/74 | 273/124 |
(Approximate lbs./kg) |
|
|
|
*Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter main- tenance. Use in extreme cold temperatures may require nontoxic
TECHNICAL SERVICE
You my have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Productsʼ Technical Service Department at
ACCESSORIES
HOSE CONNECTOR KIT
HA3230 for Model 160-IF HA3231 for Model 280-IF
Purchase accessories and parts from your nearest dealer or service center. If they can not supply these accessories or parts, either contact your nearest parts dealer or DESA Heating Products at
FLEXIBLE VENT
HOSE
HA3220 for Model
HA3221 for Model 280-IF
Model
EXTERNAL THERMOSTAT - HA3210