Desa CGR50NA, CGR35NA Operating Heater, Continued, Manual Lighting Procedure, Blower Operation

Models: CGR65BNA CGR50NA CGR50BNA CGR65NA CGR35NA

1 44
Download 44 pages 7.39 Kb
Page 23
Image 23
MANUAL LIGHTING PROCEDURE

OPERATING HEATER

Continued

MANUAL LIGHTING PROCEDURE

1.Remove lower front access panel on heater.

2.Locate pilot. Pilot is attached to the front of burner.

3.Follow steps 1 through 6 under Lighting Instructions, pages 21 and 22.

4.With control knob depressed, strike match. Hold match to pilot until pilot lights.

5.Follow steps 8 through 11 under Lighting Instructions, page 22.

BLOWER OPERATION

(For Models with Blower)

WARNING

WARNING ICON

G 001

This heater has a three-prong, grounded electrical plug. This plug helps protect you against electrical shock. Only connect plug to a properly grounded, three-prong receptacle. Do not cut or remove the grounding prong from this plug.

1.Plug power cord into a standard 115 volt, 60 hertz outlet.

2.Turn the blower control to either the AUTO or ON position. In the AUTO position, as the heater begins to heat, the blower will automatically come on. The blower will remain on until the burner shuts off and cools down. In the ON position, the blower will stay on constantly. Turn the blower control to the OFF position to stop the blower at any time.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1.Fully depress control knob in any position other than PILOT to shut off burner and pilot.

2.If equipped, turn blower control to OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob to the PILOT position. At this setting, only the pilot remains lit.

23

100792

Page 23
Image 23
Desa CGR50NA Operating Heater, Continued, Manual Lighting Procedure, Blower Operation, To Turn Off Gas To Appliance