Desa CGR35NA, CGR65NA, CGR50BNA, CGR50NA, CGR65BNA Trouble Shooting, Continued, Burner fails to

Models: CGR65BNA CGR50NA CGR50BNA CGR65NA CGR35NA

1 44
Download 44 pages 7.39 Kb
Page 30
Image 30
Burner fails to

TROUBLE-

SHOOTING

Continued

30

OBSERVED

POSSIBLE

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

Burner fails to

1.

Pilot flame not lit.

1.

Light pilot burner (see

respond to thermo-

 

 

 

Lighting Instructions,

stat.

 

 

 

page 32).

 

2.

Pilot flame not prop-

2.

Pilot flame needs

 

 

erly heating end of

 

adjusting. Contact a

 

 

thermocouple.

 

qualified service person.

 

3.

Pilot burner orifice

3.

Clean pilot burner (see

 

 

clogged or damaged.

 

Cleaning and Mainte-

 

 

 

 

nance, page 26).

 

4.

Control valve defec-

4.

Replace control valve.

 

 

tive.

 

 

 

5.

Temperature at ther-

 

 

 

 

mostat bulb satisfied.

 

 

 

 

 

 

 

Heater produces a

1.

Air in gas line.

1.

Operate burner until air

whistling noise when

 

 

 

is removed from line.

burner is lit.

 

 

 

Have gas line checked

 

 

 

 

by local natural gas

 

 

 

 

company.

 

2.

Air passageways on

2.

Observe minimum

 

 

heater blocked.

 

installation clearances

 

 

 

 

(see Figure 3, page 7).

 

3.

Dirty or partially

3.

Clean burner (see

 

 

clogged burner orifice.

 

Cleaning and Mainte-

 

 

 

 

nance, page 26) or

 

 

 

 

replace burner orifice.

 

 

 

 

Heater produces a

1. Metal expanding while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling.

 

excessive, contact

or shut off.

 

 

 

qualified service person.

100792

Page 30
Image 30
Desa CGR35NA, CGR65NA, CGR50BNA, CGR50NA, CGR65BNA installation manual Trouble Shooting, Continued, Burner fails to