Desa CGR65NA, CGR35NA, CGR50BNA Trouble- Shooting, Continued, If you smell gas Shut off gas supply

Models: CGR65BNA CGR50NA CGR50BNA CGR65NA CGR35NA

1 44
Download 44 pages 7.39 Kb
Page 31
Image 31
If you smell gas

TROUBLE- SHOOTING

Continued

WARNING

WARNING ICON

G 001

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

REMEDY

PROBLEM

CAUSE

 

 

 

 

 

Heater produces

1.

Heater burning vapors

1.

Ventilate room. Stop

unwanted odors.

 

from paint, hair spray,

 

using odor causing

 

 

glues, etc.

 

products while heater is

 

2.

Gas leak. See Warn-

 

running.

 

 

ing statement at

2.

Find and correct all

 

 

top of page.

 

leaks (see Checking Gas

 

 

 

 

Connections, page 13).

 

 

 

 

 

Heater shuts off in

1.

Heater not venting

1.

Check venting system.

use.

 

correctly. Vent safety

 

If damaged or blocked,

 

 

switch shuts off

 

repair. If venting

 

 

heater.

 

system is OK, have

 

 

 

 

qualified service person

 

 

 

 

replace vent safety

 

 

 

 

switch, wire harness, or

 

 

 

 

thermocouple inter-

 

 

 

 

rupter.

 

2.

Low line pressure.

2.

Contact local natural

 

 

 

 

gas company.

 

3.

Pilot partially clogged.

3.

Clean pilot (see Clean-

 

 

 

 

ing and Maintenance,

 

 

 

 

page 26).

 

 

 

 

 

Gas odor even when

1.

Gas leak. See Warn-

1.

Find and correct all

control knob is in

 

ing statement at

 

leaks (see Checking Gas

OFF position.

 

top of page.

 

Connections, page 13).

 

2.

Control valve damaged.

2.

Replace control valve.

 

 

 

 

 

Gas odor during

1.

Foreign matter be-

combustion.

 

tween control valve

 

 

and burner.

 

2.

Gas leak. See Warn-

 

 

ing statement at

 

 

top of page.

 

3.

Foreign fumes in area

 

 

of heater being drawn

 

 

through burner com-

 

 

bustion.

1.Take apart gas tubing and remove foreign matter.

2.Find and correct all leaks (see Checking Gas Connections, page 13).

3.Ventilate area around heater to remove any foreign fumes.

31

100792

Page 31
Image 31
Desa CGR65NA, CGR35NA, CGR50BNA, CGR50NA, CGR65BNA Trouble- Shooting, Continued, If you smell gas Shut off gas supply