![Specifications](/images/new-backgrounds/46233/4623363x1.webp)
Specifications
CCL3018PR and CCL3018PRA
• Rating (Variable): 16,000/30,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
CCL3018NR and CCL3018NRA
• Rating (Variable): 16,000/30,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.
CCL3024PR, CCL3924PRA and
CCL3939PR
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
CCL3024NR, CCL3924NRA and
CCL3939NR
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.
CCL3930PR and CCL3930PRA
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8.0" W.C.
• Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C.
CCL3930NR and CCL3930NRA
• Rating (Variable): 20,000/39,000 Btu/Hr
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3.5" W.C.
• Inlet Gas Pressure (in. of water): Max - 10.5" W.C., Min* - 5" W.C.
* For the purpose of input adjustment
Wiring Diagram
|
| Black |
| ||
On | Receiver |
| |||
Off | Red |
| |||
Remote |
|
| |||
|
|
|
|
| |
|
|
|
|
|
|
Technical Service
You may have further questions about installation, operation or troubleshooting. If so, contact DESA Heating Products’Technical Service Department at
Thermopile
TPTH TH
Gas Control
TPTH TP
Red
White
model and serial numbers of your heater ready. You can also visit DESA Heating Products’techni- cal service web site at www.desatech.com.
Service Hints
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local propane/LP gas supplier.
32 | www.desatech.com |