SAFETY INFORMATION

Continued

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.This heater shall not be installed in a bedroom or bathroom unless installed as a vented appli- ance (see Installing Damper Clamp Accessory for Vented Operation, page 11).

6.Before installing in a solid fuel burning fire- place, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater.

7.Do not burn solid-fuel in a masonry or UL127 factory-built fireplace in which a vent-free room heater is installed.

8.If fireplace has glass doors, never oper- ate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

9.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking may occur due to log curing and heater burning manufacturing residues.

10.To prevent the creation of soot, follow the instruc- tions in Cleaning and Maintenance, page 23.

11.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

12.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5. If heater keeps shutting off, see Troubleshooting, page 24.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

17.Turn heater off and let cool before servicing, install- ing or repairing. Make sure the remote selector switch is in the OFF position. Only a qualified ser- vice person should install, service or repair heater.

18.Make sure the remote selector switch is in the OFF position when you are away from home for long periods of time.

19.This heater must not be connected to any external electrical source.

20.Operating heater above elevations of 4,500 feet may cause pilot outage.

21.Provide adequate clearances around air openings.

Local Codes

Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

State of Massachusetts: The installa- tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

www.desatech.com111161-01H

Page 4
Image 4
Desa CHL3924NR installation manual Local Codes

CHL3924NR specifications

Desa CHL3924NR is an innovative and versatile heating solution designed to meet the demands of modern living. This unit is particularly favored for its combination of efficiency, performance, and advanced technology, making it an ideal choice for homeowners looking for effective heating options.

One of the standout features of the Desa CHL3924NR is its impressive heating capacity. With a powerful design, it can deliver substantial warmth to medium to large spaces while maintaining a user-friendly operation. The unit boasts a range of heating settings, allowing users to customize the temperature according to their preferences and comfort. This flexibility not only enhances user experience but also optimizes energy consumption, contributing to lower utility bills.

Furthermore, the CHL3924NR incorporates cutting-edge technology to ensure reliable and efficient performance. The unit comes with a state-of-the-art digital thermostat that provides precise temperature control. This feature allows for easy monitoring and adjustment, ensuring that a comfortable environment is maintained effortlessly.

Energy efficiency is a hallmark of the Desa CHL3924NR. It is designed to minimize energy waste while maximizing output, making it an environmentally conscious choice. The unit's efficient fuel consumption means it operates with lower emissions compared to traditional heating systems, aligning with the growing trend towards sustainable living.

Durability is another significant characteristic of the Desa CHL3924NR. Constructed with high-quality materials, this heating unit is built to last, and its robust design can withstand the rigors of daily use. Coupled with a sleek, modern aesthetic, it seamlessly integrates into various home décors.

Safety features are paramount in the design of the CHL3924NR, ensuring peace of mind during operation. The unit is equipped with safety shut-off mechanisms, preventing overheating and potential hazards.

In conclusion, the Desa CHL3924NR stands out as a reliable, efficient, and stylish heating solution, perfect for contemporary homes. Its combination of advanced technology, user-friendly features, energy efficiency, and safety make it an excellent choice for anyone looking to enhance their heating experience. Whether for a cozy night in or providing warmth during colder months, the Desa CHL3924NR delivers exceptional performance that meets the needs of today’s consumers.