Desa RL2718PA/NA, CRL3124PA/NA, CCL3018PA/NA WARNING If you smell gas Shut off gas supply

Models: CCL3018PTA/NTA RL2718PA/NA CCL3924PA/NA CCL3924PTA/NTA CCL3930PTB/NTB CCL3018PA/NA CRL3124PA/NA

1 40
Download 40 pages 62.8 Kb
Page 27
Image 27
 WARNING: If you smell gas

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Open window and ventilate

odors

 

paint, hair spray, glues, clean-

 

room. Stop using odor caus-

 

 

ers, chemicals, new carpet,

 

ing products while heater is

 

 

etc. (See IMPORTANT state-

2.

running

 

2.

ment above)

Locate and correct all leaks

 

Gas leak. See Warning

 

(see Checking Gas Connec-

 

 

statement above

 

tions, page 14)

 

 

 

 

 

 

Heater shuts off in use

1.

Not enough fresh air is avail-

1.

Open window and/or door for

(ODS operates) temperature

2.

able

2.

ventilation

drops to a lower than ideal level

Low line pressure

Contact local propane/LP or

before log set comes back on

3.

ODS/pilot is partially

3.

natural gas company

 

Clean ODS/pilot (see Cleaning

 

 

clogged

 

and Maintenance, page 23)

 

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement above

 

(see Checking Gas Connec-

 

2.

Control valve defective

2.

tions, page 14)

 

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

2.

trol valve and burner

2.

remove foreign matter

 

Gas leak. See Warning

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Connec-

 

 

 

 

tions, page 14)

 

 

 

 

 

 

Logs set cycles to pilot, but

1.

Thermostat sensing bulb needs

1.

Reposition thermostat sensing

room

 

to be repositioned

 

bulb (see Optional Positioning

 

 

 

 

of Thermostat Sensing Bulb,

 

 

 

 

beginning on page 28