TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
|
|
|
|
|
|
Heater produces unwanted | 1. | Heater burning vapors from | 1. | Open window and ventilate | |
odors |
| paint, hair spray, glues, clean- |
| room. Stop using odor caus- | |
|
| ers, chemicals, new carpet, |
| ing products while heater is | |
|
| etc. (See IMPORTANT state- | 2. | running | |
| 2. | ment above) | Locate and correct all leaks | ||
| Gas leak. See Warning |
| (see Checking Gas Connec- | ||
|
| statement above |
| tions, page 14) | |
|
|
|
|
|
|
Heater shuts off in use | 1. | Not enough fresh air is avail- | 1. | Open window and/or door for | |
(ODS operates) temperature | 2. | able | 2. | ventilation | |
drops to a lower than ideal level | Low line pressure | Contact local propane/LP or | |||
before log set comes back on | 3. | ODS/pilot is partially | 3. | natural gas company | |
| Clean ODS/pilot (see Cleaning | ||||
|
| clogged |
| and Maintenance, page 23) | |
|
|
|
|
|
|
Gas odor even when control | 1. | Gas leak. See Warning | 1. | Locate and correct all leaks | |
knob is in OFF position |
| statement above |
| (see Checking Gas Connec- | |
| 2. | Control valve defective | 2. | tions, page 14) | |
| Replace control valve | ||||
|
|
|
|
| |
Gas odor during combustion | 1. | Foreign matter between con- | 1. | Take apart gas tubing and |
|
| 2. | trol valve and burner | 2. | remove foreign matter | |
| Gas leak. See Warning | Locate and correct all leaks | |||
|
| statement above |
| (see Checking Gas Connec- | |
|
|
|
| tions, page 14) | |
|
|
|
|
|
|
Logs set cycles to pilot, but | 1. | Thermostat sensing bulb needs | 1. | Reposition thermostat sensing | |
room |
| to be repositioned |
| bulb (see Optional Positioning | |
|
|
|
| of Thermostat Sensing Bulb, | |
|
|
|
| beginning on page 28 |
www.desatech.com | 27 |