Desa CCL3930PTB/NTB Installation, Continued, Minimum Fireplace Clearance, Side Wall, Depth

Models: CCL3018PTA/NTA RL2718PA/NA CCL3924PA/NA CCL3924PTA/NTA CCL3930PTB/NTB CCL3018PA/NA CRL3124PA/NA

1 40
Download 40 pages 62.8 Kb
Page 9
Image 9
INSTALLATION

INSTALLATION

Continued

INSTALLATION AND CLEARANCES (Vent-Free Operation Only)

MINIMUM FIREPLACE CLEARANCE WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

 

Ceiling

18", 24", 30"

 

16"

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

Minimum Firebox

Log

 

 

 

 

Front

Rear *

Size

 

Height

 

Depth

Width

Width

 

 

 

 

 

 

 

 

18"

17"

14"

24"

 

20"

24"

17"

14"

28"

 

21"

30"

17"

14"

34"

 

24"

* Measured at 14" depth.

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127- listed manufactured fireplace or certified vent-free firebox.

Minimum Clearances For Side Combustible Material, Side Wall and

Ceiling

A. Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combus- tible material must be 4" from the side of the fireplace opening (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B. Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for

Combustible to Wall

NOTICE: Manual control heaters maybeusedasaventedproduct. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel, page 10. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombus- tible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5, page 10 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

113097-01Ewww.desatech.com

Page 9
Image 9
Desa CCL3930PTB/NTB Installation, Continued, Minimum Fireplace Clearance, To Combustible Materials, Side Wall, Depth