Desa CCL3018PTA/NTA Installing Heater Base Assembly, Chimney, Minimum Permanent, Area sq. in

Models: CCL3018PTA/NTA RL2718PA/NA CCL3924PA/NA CCL3924PTA/NTA CCL3930PTB/NTB CCL3018PA/NA CRL3124PA/NA

1 40
Download 40 pages 62.8 Kb
Page 12
Image 12
Chimney

INSTALLATION

Continued

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. in.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Area of Various Standard

Round Flues

Diameter (in.)

Area (sq. in.)

5"

0 sq. inches

6"

9 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

INSTALLING HEATER BASE ASSEMBLY

Minimum Permanent CAUTION: Do not remove the dataplatesattachedtotheheater base assembly. The data plates contain important warranty and safety information.

Area of Various Standard WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

Area (sq. in.) WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and controls being damaged. Raise fireplace floor with noncombus- tible material. Make sure material is secure.

INSTALLING HEATER BASE ASSEMBLY CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base as- sembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning Of Thermostat Sensing Bulb, page 28.

Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose (not provided) (if allowed by local codes)

• sealant resistant to propane (propane/LP) gas, not provided

• electric drill with 3/16" drill bit

• flathead screwdriver

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper position on heater base, see Installing Logs on page 16.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

Flexible Gas Hose

(if allowed by local codes)

Heater Gas

Regulator

Fitting Installation Items Needed

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

12

www.desatech.com

113097-01E

Page 12
Image 12
Desa CCL3018PTA/NTA Installing Heater Base Assembly, Chimney, Minimum Permanent, Area of Various Standard Round Flues