OPERATING HEATER

Continued

Thermostat-Controlled

Models

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result causing property damage, per- sonal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before run- ning heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

113097-01E

www.desatech.com

21

Page 21
Image 21
Desa CRL3124PA/NA, CCL3018PA/NA Thermostat-Controlled Models, For Your Safety Read Before Lighting, Lighting Instructions

CCL3018PTA/NTA, RL2718PA/NA, CCL3924PA/NA, CCL3924PTA/NTA, CCL3930PTB/NTB specifications

Desa CCL3924PTA/NTA, CCL3018PTA/NTA, CCL3930PTB/NTB, CCL3924PA/NA, and CCL3018PA/NA are a lineup of advanced cooling units designed to meet diverse needs in thermal management for residential, commercial, and industrial applications. Each model brings together a blend of innovative technology and user-friendly features that ensure efficient performance and reliability.

The CCL3924PTA/NTA model is designed for high-performance cooling, offering a blend of efficiency and sustainable operation. Its inverter technology allows for variable speed control, leading to lower energy consumption and quieter operation. This model is particularly suited for larger spaces, providing consistent cooling throughout the environment while maintaining energy efficiency.

CCL3018PTA/NTA is a compact unit that excels in environments with space constraints. Despite its smaller size, it delivers robust cooling performance, making it ideal for residential settings or small office spaces. Its lightweight design and easy installation capabilities reduce downtime and allow for swift setup, while its smart thermostat controls enable precise temperature management.

For environments that require intensive cooling, the CCL3930PTB/NTB model stands out with its powerful compressor and larger cooling capacity. This unit is engineered for industrial applications, featuring heavy-duty components that ensure long operational life even in demanding conditions. Its multi-zone capability allows users to cool several areas simultaneously, providing tailored solutions for complex layouts.

The CCL3924PA/NA variant focuses on energy efficiency without compromising on cooling power. This model is equipped with advanced thermal insulation technology, minimizing heat exchange and enhancing its performance during peak usage. Users benefit from significant energy savings, making it an environmentally friendly choice for those concerned about carbon footprints.

Lastly, the CCL3018PA/NA brings versatility with its dual-function capability. This model not only serves as a cooling unit but can also function as a heater, making it a year-round solution for climate control. Its efficient heat pump technology makes it an ideal choice for locations with varying seasonal temperatures, ensuring comfort throughout the year.

In conclusion, the Desa lineup of cooling solutions combines cutting-edge technology, energy efficiency, and user-friendly features, catering to a wide array of applications and user needs. Each model has been engineered with a focus on durability and reliability, making them a smart investment for anyone looking to enhance their indoor climate control systems.