OPERATING HEATER

Continued

5.Slightly depress and turn control knob

counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 30).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Slightly depress and turn control knob

counterclockwise to desired heat- ing level. The burner(s) should light. Set control knob to any heat level between HI and LO.

WARNING: Do not operate heater between PILOT and HI positions.

Ignitor Button

Control Knob

 

Figure 30 - Control Knob and Ignitor

Button Location

Ignitor

Pilot Burner

Electrode

 

Thermocouple

Figure 31 - Pilot

 VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides re- alistic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

 TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Press in and turn control knob clockwise

to the HI position.

2. Turn control knob clockwise to the pilot position.

3. Press in control knob and turn clockwise to the OFF position.

Shutting Off Burner(s) Only (pilot stays lit)

1. Turn control knob clockwise to the HI position.

2. Press in and turn control knob clockwise to the pilot position.

 MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, pages 19 and 20.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, column 1.  

20

www.desatech.com

113097-01E

Page 20
Image 20
Desa RL2718PA/NA Operating Heater,  VARIABLE Control Operation,  TO Turn OFF GAS To Appliance,  MANUAL Lighting Procedure

CCL3018PTA/NTA, RL2718PA/NA, CCL3924PA/NA, CCL3924PTA/NTA, CCL3930PTB/NTB specifications

Desa CCL3924PTA/NTA, CCL3018PTA/NTA, CCL3930PTB/NTB, CCL3924PA/NA, and CCL3018PA/NA are a lineup of advanced cooling units designed to meet diverse needs in thermal management for residential, commercial, and industrial applications. Each model brings together a blend of innovative technology and user-friendly features that ensure efficient performance and reliability.

The CCL3924PTA/NTA model is designed for high-performance cooling, offering a blend of efficiency and sustainable operation. Its inverter technology allows for variable speed control, leading to lower energy consumption and quieter operation. This model is particularly suited for larger spaces, providing consistent cooling throughout the environment while maintaining energy efficiency.

CCL3018PTA/NTA is a compact unit that excels in environments with space constraints. Despite its smaller size, it delivers robust cooling performance, making it ideal for residential settings or small office spaces. Its lightweight design and easy installation capabilities reduce downtime and allow for swift setup, while its smart thermostat controls enable precise temperature management.

For environments that require intensive cooling, the CCL3930PTB/NTB model stands out with its powerful compressor and larger cooling capacity. This unit is engineered for industrial applications, featuring heavy-duty components that ensure long operational life even in demanding conditions. Its multi-zone capability allows users to cool several areas simultaneously, providing tailored solutions for complex layouts.

The CCL3924PA/NA variant focuses on energy efficiency without compromising on cooling power. This model is equipped with advanced thermal insulation technology, minimizing heat exchange and enhancing its performance during peak usage. Users benefit from significant energy savings, making it an environmentally friendly choice for those concerned about carbon footprints.

Lastly, the CCL3018PA/NA brings versatility with its dual-function capability. This model not only serves as a cooling unit but can also function as a heater, making it a year-round solution for climate control. Its efficient heat pump technology makes it an ideal choice for locations with varying seasonal temperatures, ensuring comfort throughout the year.

In conclusion, the Desa lineup of cooling solutions combines cutting-edge technology, energy efficiency, and user-friendly features, catering to a wide array of applications and user needs. Each model has been engineered with a focus on durability and reliability, making them a smart investment for anyone looking to enhance their indoor climate control systems.