Desa CCL3924PA/NA, CRL3124PA/NA, CCL3018PA/NA, CCL3930PTB/NTB Safety Information, Local Codes

Models: CCL3018PTA/NTA RL2718PA/NA CCL3924PA/NA CCL3924PTA/NTA CCL3930PTB/NTB CCL3018PA/NA CRL3124PA/NA

1 40
Download 40 pages 62.8 Kb
Page 4
Image 4

SAFETY INFORMATION

Continued

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.This heater shall not be installed in a bedroom or bathroom unless installed as a vented appli- ance (Variable Manually-Controlled Models Only) (see Installing Damper Clamp Acces- sory for Vented Operation, page 11).

6.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater.

7.Do not burn solid-fuel in a masonry or UL127 factory-built fireplace in which a vent-free room heater is installed.

8.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fire- place will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

9.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufac- turing residues.

10.To prevent the creation of soot, follow the instruc- tions in Cleaning and Maintenance, page 23.

11.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

12.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen De- pletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5. If heater keeps shutting off, see Troubleshooting, page 25.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dime- sized or larger).

17.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

18.Operating heater above elevations of 4,500 feet could cause pilot outage.

19.Provide adequate clearances around air openings.

Local Codes

Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat- est edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

State of Massachusetts: The installa- tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

www.desatech.com113097-01E

Page 4
Image 4
Desa CCL3924PA/NA, CRL3124PA/NA, CCL3018PA/NA, CCL3930PTB/NTB, CCL3924PTA/NTA, CCL3018PTA/NTA Safety Information, Local Codes

CCL3018PTA/NTA, RL2718PA/NA, CCL3924PA/NA, CCL3924PTA/NTA, CCL3930PTB/NTB specifications

Desa CCL3924PTA/NTA, CCL3018PTA/NTA, CCL3930PTB/NTB, CCL3924PA/NA, and CCL3018PA/NA are a lineup of advanced cooling units designed to meet diverse needs in thermal management for residential, commercial, and industrial applications. Each model brings together a blend of innovative technology and user-friendly features that ensure efficient performance and reliability.

The CCL3924PTA/NTA model is designed for high-performance cooling, offering a blend of efficiency and sustainable operation. Its inverter technology allows for variable speed control, leading to lower energy consumption and quieter operation. This model is particularly suited for larger spaces, providing consistent cooling throughout the environment while maintaining energy efficiency.

CCL3018PTA/NTA is a compact unit that excels in environments with space constraints. Despite its smaller size, it delivers robust cooling performance, making it ideal for residential settings or small office spaces. Its lightweight design and easy installation capabilities reduce downtime and allow for swift setup, while its smart thermostat controls enable precise temperature management.

For environments that require intensive cooling, the CCL3930PTB/NTB model stands out with its powerful compressor and larger cooling capacity. This unit is engineered for industrial applications, featuring heavy-duty components that ensure long operational life even in demanding conditions. Its multi-zone capability allows users to cool several areas simultaneously, providing tailored solutions for complex layouts.

The CCL3924PA/NA variant focuses on energy efficiency without compromising on cooling power. This model is equipped with advanced thermal insulation technology, minimizing heat exchange and enhancing its performance during peak usage. Users benefit from significant energy savings, making it an environmentally friendly choice for those concerned about carbon footprints.

Lastly, the CCL3018PA/NA brings versatility with its dual-function capability. This model not only serves as a cooling unit but can also function as a heater, making it a year-round solution for climate control. Its efficient heat pump technology makes it an ideal choice for locations with varying seasonal temperatures, ensuring comfort throughout the year.

In conclusion, the Desa lineup of cooling solutions combines cutting-edge technology, energy efficiency, and user-friendly features, catering to a wide array of applications and user needs. Each model has been engineered with a focus on durability and reliability, making them a smart investment for anyone looking to enhance their indoor climate control systems.