Vulcan-Hart ICM24 ML-52470 Installation, Operation, and Care of, Gas Infrared Cheese Melters

Models: ICM24 ML-52470, 52476, ICM36 ML-52471, 52477, ICM48 ML-52472, 52478, ICM60 ML-52743,52479, ICM72 ML-52474, 52480 52480 ICM24 ML-52470

1 8
Download 8 pages 18.09 Kb
Page 3
Image 3
Installation, Operation, and Care of

Installation, Operation, and Care of

MODELS ICM24, ICM36, ICM48, ICM60 & ICM72

GAS INFRARED CHEESE MELTERS

KEEP THIS MANUAL FOR FUTURE USE

GENERAL

The Vulcan Gas Infrared Cheese Melters use efficient gas heat and are available in 24, 36, 48, 60, or 72 inch widths. Each model has one or two burners; each burner has its own pilot light and control knob.

GAS RATINGS

Model

ICM24

ICM36

ICM48

ICM60

ICM72

 

 

 

 

 

 

BTU Rating

20,000 BTU/hr

30,000 BTU/hr

40,000 BTU/hr

50,000 BTU/hr

60,000 BTU/hr

 

 

 

 

 

 

INSTALLATION

UNPACKING

Immediately after unpacking, check for possible shipping damage. If the Cheese Melter is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.

Before installing, verify that the gas (natural or propane) agrees with the specifications on the rating plate located on the front.

LOCATION

The area around the appliance must be kept free and clear from combustibles. The area in front of and above the Cheese Melter must be clear to avoid any obstruction to the flow of combustion and ventilation air. Means must be provided for adequate air supply and adequate clearance for air openings into the combustion chamber.

Adequate clearance must be provided in front and at the sides of the appliance for servicing and proper operation.

The Cheese Melter can be installed in combustible or noncombustible locations. Clearance from combustible construction must be a minimum of 6 inches from the sides and 0 inches from the back. There are no minimum clearances from noncombustible construction.

The Cheese Melter can be installed on a noncombustible counter, with or without 4" legs, or mounted on a combustible or noncombustible wall: Leg kits and wall mounting brackets are available from your Vulcan-Authorized Service Office for your model Cheese Melter. If installing the Cheese Melter on a combustible counter, the 4" legs are required.

– 3 –