Image 17
Figure 21 - Gas Connection

INSTALLATION

Continued

We recommend that you install a sediment trap in supply line as shown in Figure 21. Locate sedi- ment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped mat- ter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

Approved

Flexible

CSA Design-Certified

Equipment Shutoff Valve

Gas Line

With 1/8" NPT Tap*

 

 

Propane/LP

 

From External

 

Regulator (11"

 

W.C.** to 14"

 

W.C. Pressure)

 

NATURAL

 

From Gas

 

Meter (5"

 

W.C.** to 10.5"

 

W.C. Pressure)

3" Minimum

Pipe Nipple Cap Tee Joint

Sediment Trap

Figure 21 - Gas Connection

*Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Ac- cessories, pages 36 and 37.

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

Phillips screwdriver

sealant (resistant to propane/LP gas, not provided)

1.Remove screws that attach branch support to fireplace (see Figure 22). Carefully lift up branch support and remove from fireplace (see Figure 22).

NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow accessibility fromthefireplace(seeFigure22). The flexible gas supply line con- nection to the equipment shutoff valve should be accessible.

2.Route flexible gas line, included, from fireplace control to equipment shutoff valve through side or rear access holes in outer casing.

3.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve (see Fig- ure 23, page 18).

CONNECTING FIREPLACE TO GAS SUPPLY CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings.

Flexible

Branch

Gas Line

Support

Figure 22 - Removing Branch Support
From Fireplace

113110-01A