INSTALLATION

Continued

Equipment Shutoff Valve

Propane/LP

Supply Tank

Gas Control Valve

Figure 25 - Checking Gas Joints

(Propane/LP Only)

Equipment

Shutoff Valve

Gas

Meter

Gas Control

Valve

Figure 26 - Checking Gas Joints

(Natural Gas Only)

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Figure 24, page 18).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP sup- ply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to gas control valve (see Figures 25 or 26). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fireplace, pages 22 through 25). Check all other inter- nal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 23).

OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL ACCESSORIES (GHRCB Series & GHRCTB Series)

Installing Receiver

1.Remove screws.

2.Disconnect switch wires from the control valve.

3.Remove switch plate (see Figure 27). Discard switch plate after removing. Save the screws.

4.Locate the battery clip mounted on the back of the receiver (see Figure 28).

5.Slide 9-volt battery (not included) through the clip.

6.Attach the terminal wires to the battery (see Figure 28).

7.Connect wires as shown in Figure 30, page 20.

8.Install remote receiver unit onto fireplace base using the two screws removed in step one (see Figure 29, page 20).

 

Switch

Screw

Plate

 

Red Wire

Black

Wire

Figure 27 - Switch Plate and Wiring

Harness

Receiver

Terminal

Wires

Battery Clip

9-Volt Battery

Figure 28 - Attaching Battery to Receiver

113110-01A

www.desatech.com

19

Page 19
Image 19
Desa VMH26NRB, EFS26NRA, EFS26PRA, VMH26PRB Pressure Testing Fireplace Gas Connections, Installing Receiver