Desa VMH26PRB, EFS26NRA Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy

Models: VMH26NRB EFS26PRA EFS26NRA VMH26PRB

1 40
Download 40 pages 33.85 Kb
Page 30
Image 30
(see Cleaning and Mainte-

TROUBLESHOOTING

 

 

Continued

 

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Slight smoke or odor during ini-

1.

Residues from manufactur-

1.

Problem will stop after a few

tial operation

 

ing processes and log curing

 

hours of operation

 

2.

Not enough air

2.

Check burner for dirt and de-

 

 

 

 

bris. If found, clean burner

 

 

 

 

(see Cleaning and Mainte-

 

 

 

 

nance, pages 26 and 27)

 

3.

Gas regulator defective

3.

Replace gas regulator

Fireplace produces a whistling 1. Turning control knob to HI

noise when burner is lit

position when burner is cold

2.

Air in gas line

3.

Air passageways on fireplace

 

blocked

4.

Dirty or partially clogged

 

burner orifice

1.Turn control knob to LO posi- tion and let warm up for a minute

2.Operate burner until air is re- moved from line. Have gas line checked by local natural gas company

3.Observe minimum installation clearances (see pages 10 through 12)

4.Clean burner (see Cleaning and Maintenance, pages 26 and 27) or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture polish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn fireplace off when using furniture polish, wax, carpet cleaners, or similar products

Moisture/condensation noticed on

1. Not enough combustion/ven-

1. Refer to Air for Combustion

windows

tilation air

and Ventilation requirements

 

 

(page 6)