Desa FPVF33PR Continued, Conventional Fireplace Installation, Installing, Installation Clearances

Models: FPVF33PR

1 44
Download 44 pages 26.13 Kb
Page 11
Image 11
INSTALLING

INSTALLING

INSTALLATION CLEARANCES

Continued

WARNING ICONG 001WARNING

Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This will ensure safe installation.

Minimum Wall and Ceiling Clearances (see Figure 7)

A.Clearances from the side of the fireplace opening to any combustible wall should not be less than 16 inches for a cabinet mantel or 12 inches for a corner installation.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

 

 

MINIMUM CLEARANCE

Note: Clearances

42"

Side Wall - 16 " Cabinet and

are the same if

Face Mantel

 

using optional

 

Ceiling - 42" Corner Mantel

cabinet mantel or

 

Floor - 0"

built-in installation.

 

 

 

16"

 

 

Face or

 

 

Cabinet

 

 

Mantel

 

 

12"

 

 

Corner

 

 

Mantel

 

Figure 7 - Minimum Clearance to Wall and Ceiling

CONVENTIONAL FIREPLACE INSTALLATION

Conventional installation of this fireplace involves installing fireplace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions below to install the fireplace in this manner.

WARNING

WARNING ICON

G 001

For conventional installation, it is recommended you use the cabinet mantel, corner mantel, face mantel, or hearth bases speci- fied in this manual. Surface clearances may not be sufficient with other cabinet mantels and hearth bases. This may create a fire hazard. See Accessories, pages 34 and 35 for correct mantels and hearth bases.

Note: The instructions below show installation using the cabinet mantel and the G3000F/G3001U hearth base accessories. The hearth base accessory shown is optional for this installation. You can install fireplace and cabinet mantel directly on the floor. The corner mantel and face mantel accessories cannot be installed with the G3000F/G3001U hearth base. You must install corner and face mantel directly on the floor. If mounting fireplace and cabinet mantel to the floor or using face mantel or corner mantel, an optional G3005 Slim Base kit may be installed.

1.Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc- tions are included with each accessory.

2.Install a properly grounded, 120 volt three-prong electrical outlet at fireplace location if an outlet is not there. If possible, locate outlet so cabinet mantel

will cover it when installed (see Figure 8, page 12).