TROUBLE- | OBSERVED | POSSIBLE |
|
| ||
PROBLEM | CAUSE | REMEDY | ||||
SHOOTING | ||||||
|
|
|
|
| ||
When ignitor button | 1. Gas supply turned off or | 1. | Turn on gas supply or | |||
Continued | ||||||
is pressed, there is |
| manual shutoff valve |
| open manual shutoff | ||
|
|
| ||||
| spark at ODS/pilot |
| closed |
| valve | |
| but no ignition | 2. | Control knob not in | 2. | Turn control knob to | |
|
|
| PILOT position |
| PILOT position | |
|
| 3. | Control knob not | 3. | Press in control knob | |
|
|
| pressed in while in |
| while in PILOT position | |
|
|
| PILOT position |
|
| |
|
| 4. | Air in gas lines when | 4. | Continue holding down | |
|
|
| installed |
| control knob. Repeat | |
|
|
|
|
| igniting operation until | |
|
|
|
|
| air is removed | |
|
| 5. | ODS/pilot is clogged | 5. | Clean ODS/pilot (see | |
|
|
|
|
| Cleaning and Mainte- | |
|
|
|
|
| nance, page 28) or | |
|
|
|
|
| replace ODS/pilot | |
|
|
|
|
| assembly | |
|
| 6. | Gas regulator setting is | 6. | Replace gas regulator | |
|
|
| not correct |
|
| |
|
|
|
|
|
| |
| ODS/pilot lights but | 1. | Control knob not fully | 1. | Press in control knob | |
| flame goes out when |
| pressed in |
| fully | |
| control knob is | 2. | Control knob not | 2. | After ODS/pilot lights, | |
| released |
| pressed in long enough |
| keep control knob | |
|
|
|
|
| pressed in 30 seconds | |
|
| 3. | Manual shutoff valve | 3. | Fully open manual shut- | |
|
|
| not fully open |
| off valve | |
|
| 4. | Thermocouple connec- | 4. | Hand tighten until snug, | |
|
|
| tion loose at control |
| then tighten 1/4 turn | |
|
|
| valve |
| more | |
|
| 5. | Pilot flame not touching | 5. | A) Contact local pro- | |
|
|
| thermocouple, which |
| pane/LP g s company | |
|
|
| allows thermocouple to |
|
| |
|
|
| cool, causing pilot flame |
| B) Clean ODS/pilot (see | |
|
|
| to go out. This problem |
| Cleaning and Mainte- | |
|
|
| could be caused by one |
| nance, page 28) or | |
|
|
| or both of the following: |
| replace ODS/pilot | |
|
|
| A) Low gas pressure |
| assembly | |
|
|
| B) Dirty or partially |
|
| |
|
|
| clogged ODS/pilot |
|
| |
|
| 6. | Thermocouple damaged | 6. | Replace thermocouple | |
|
| 7. | Control valve damaged | 7. | Replace control valve | |
|
| 8. | On thermostat models, | 8. | Wait one minute for | |
|
|
| safety interlock system |
| safety interlock system | |
|
|
| has been triggered |
| to reset. Repeat ignition | |
|
|
|
|
| operation |
Continued
29
103280