Desa FPVF33PR Variable Control Operation, Manually-Controlled, Models, Operating, Fireplace

Models: FPVF33PR

1 44
Download 44 pages 26.13 Kb
Page 25
Image 25
Manually-Controlled
C-clockwise

OPERATING

6. Continue pressing control knob in. Press and release ignitor button. This will light

 

FIREPLACE

pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor

button until pilot lights.

 

Manually-Controlled

Note: If pilot does not stay lit, contact a qualified service person or gas supplier

for repairs. Until repairs are made, light pilot with match. To light pilot with

Models

match, see Manual Lighting Procedure, below.

 

Continued

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

 

release control knob.

 

 

Note: If pilot goes out, repeat steps 3 through 7.

 

 

• If control knob does not pop out when released, contact a qualified service

 

person or gas supplier for repairs.

 

 

Ignitor Electrode

 

Thermocouple

Pilot Burner

 

 

Figure 31 - Pilot

8. Slightly depress and turn control knob counterclockwise Models to the HIGH position. Both burners should light. Set control knob to either HIGH or LOW.

VARIABLE CONTROL OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glowing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.

WARNING

WARNING ICON

G 001

Do not operate heater between locked positions.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Fireplace

 

 

1.

Turn control knob clockwise

Clockwise to the HIGH position.

2.

Slightly depress control knob and turn clockwise

Clockwise to the PILOT position.

3.

Slightly depress control knob and turn clockwise

Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

 

1.

Turn control knob clockwise

Clockwise to the HIGH position.

2.

Press in and turn clockwise

Clockwise to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Follow steps 1 through 5 under Lighting Instructions, page 24.

2. Depress control knob and light pilot with match.

3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob. Now follow step 8, above.

103280

Continued 25

Page 25
Image 25
Desa FPVF33PR Variable Control Operation, Manually-Controlled, Models, Operating, Fireplace, To Turn Off Gas To Appliance