CLEANING AND MAINTENANCE
TROUBLE-
SHOOTING
Note: All troubleshooting items are listed in order of operation.
28
WARNING
WARNING ICON | G 001 |
Turn off fireplace and let cool before cleaning.
CAUTION
WARNING ICON | G 001 |
You must keep control areas, burners, and circulating air pas- sageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, etc.
ODS/PILOT AND BURNERS
• Use a vacuum cleaner or small, soft bristled brush to clean.
LOGS
•If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to properly replace logs.
•Replace log(s) if broken or chipped
WARNING
WARNING ICON | G 001 |
Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.
CAUTION
WARNING ICON | G 001 |
Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.
OBSERVED | POSSIBLE |
|
| |
PROBLEM | CAUSE | REMEDY | ||
|
|
|
|
|
When ignitor button | 1. | Ignitor electrode not con- | 1. | Reconnect ignitor cable |
is pressed, there is no |
| nected to ignitor cable |
|
|
spark at ODS/pilot | 2. | Piezo ignitor nut is loose | 2. | Tighten nut holding |
|
|
|
| piezo ignitor to base |
|
|
|
| panel of log set. Nut is |
|
|
|
| located behind base |
|
|
|
| panel. |
| 3. | Ignitor cable pinched or | 3. | Free ignitor cable if |
|
| wet |
| pinched by any metal or |
|
|
|
| tubing. Keep ignitor |
|
|
|
| cable dry |
| 4. | Broken ignitor cable | 4. | Replace ignitor cable |
| 5. | Bad piezo ignitor | 5. | Replace piezo ignitor |
| 6. | Ignitor electrode broken | 6. | Replace ignitor |
| 7. | Ignitor electrode posi- | 7. | Replace ignitor |
|
| tioned wrong |
|
|
103280