OPERATING FIREPLACE
All Models
INSPECTING BURNERS
26
BLOWER OPERATION
WARNING
This fireplace has a
Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door.
Note: Your gas logs and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.
Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.
Manual blowers on
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 32 shows a correct pilot flame pattern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.
Thermocouple | Pilot Burner | Thermocouple | Pilot Burner |
|
|
Figure 32 - Correct Pilot | Figure 33 - Incorrect Pilot |
Flame Pattern | Flame Pattern |
If pilot flame pattern is incorrect, as shown in Figure 33
•turn fireplace off (see To Turn Off Gas to Appliance, page 23 [Thermostat- controlled models} or page 25
•see Troubleshooting, pages 28 through 31