OWNER’S MANUAL

STOVE AND B-VENT BURNER SYSTEM INSTALLATION

Continued

4.Check all joints of gas supply piping system. Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Reconnect burner system and equip- ment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 33).

2.Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas burner sys- tem or opening main gas valve located on or near gas meter for natural gas burner system, or using compressed air.

3.Check all joints from propane/LP sup- ply tank or gas meter to equipment shutoff valve (see Figure 34 for pro- pane/LP or Figure 35 for natural). Ap- ply commercial leak test solution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Burner System Gas Connections

1.Open equipment shutoff valve (see Fig- ure 33).

2.Open propane/LP supply tank valve for propane/LP burner system or main gas valve located on or near gas meter for natural gas burner system.

3.Make sure control knob of burner sys- tem is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 34 for propane/LP or Figure 35 for natural). Apply commercial leak test so- lution to all gas joints. Bubbles forming show a leak. Correct all leaks at once.

5.Light burner system (see Lighting In- structions, page 19). Check all other in- ternal joints for leaks.

6.Turn off burner system (see To Turn Off Gas to Appliance, page 19).

Open

Equipment

Shutoff

Valve

Closed

Figure 33 - Equipment Shutoff Valve

Equipment

100 lb. (Min.)

Shutoff

Propane/LP

Valve

Supply Tank

Gas Valve

 

Figure 34 - Checking Gas Joints for Propane/LP Gas Burner System

Equipment

Shutoff Valve

Gas Meter

Gas Valve

Figure 35 - Checking Gas Joints for Natural Gas Burner System

Continued

107600

15

For more information, visit www.desatech.com

Page 15
Image 15
Desa FSBVBPC, FSBVBNC Pressure Testing Burner System Gas Connections, Close equipment shutoff valve see Figure