OWNER’S MANUAL
SPECIFICATIONS
| FSBVBNC | FSBVBPC |
| ||
|
|
|
Gas Type | Natural | Propane/LP |
|
|
|
Ignition | Piezo | Piezo |
|
|
|
Manifold Pressure | 3.5" w.c. | 10.0" w.c. |
|
|
|
Minimum Inlet Supply Pressure | 4.5" w.c. | 11.0" w.c. |
|
|
|
Thermal Efficiency | 70% | 70% |
|
|
|
Dimension, Inches/mm (HxWxD) |
|
|
Burner System* | 28" x 28" x 18" | 28" x 28" x 18" |
| 711.2 x 685.8 x 584.2 mm | 711.2 x 685.8 x 584.2 mm |
Carton (Insert Only) | 23" x 33" x 23" | 23" x 33" x 23" |
| 584.2 x 838.2 x 584.2mm | 584.2 x 838.2 x 584.2mm |
|
|
|
Weight, lbs/kg |
|
|
Fireplace | 70 lbs/31.8 kg | 70 lbs/31.8 kg |
Shipping | 75 lbs/34 kg | 75 lbs/34 kg |
* When installed in FMI cast iron stove body ((P)FC Series).
ACCESSORIES
Purchase these stove and burner system accessories from your local dealer. If they can not supply these accessories, call DESA International’s Sales Department at
RECEIVER AND HAND-HELD REMOTE CONTROL KIT GHRC
For all models. Allows the heater to be turned on and off conveniently.
|
| WARMER |
ON AUTO | COOLER | TEMP |
|
| |
OFF |
|
|
WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 (Not Shown)
Allows easy wall access to the operation of your burner system. This will allow you thermostatic control with the convenience of a wall switch.
WALL MOUNTED ON/OFF SWITCH - GWMS2
(Not Shown)
Allows heater to be turned on and off with a wall switch.
THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610TA
Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in this manual.
RECEIVER AND HAND-HELD THERMOSTAT REMOTE CONTROL KIT - GHRCTA
Allows the burner system to be operated in a manually or
107600 | 27 | For more information, visit www.desatech.com |